CDR-S1000
CDR-S1000
6
Fig. 3
Fig. 1
r
e
q
q
CDR Mechanical Unit
w
t
t
1. CDR Mechanical Unit Removal
a. Turn off the power and disconnect the power plug from
the service outlet.
CAUTION : Never disconnect any cable, remove any
screw or other part while the power switch is on.
b. Remove 4 screws marked
q
and 1 screw marked
w
,
and the Top Cover can be removed. (Fig. 1)
c. Disconnect the power cable / IDE cable / word clock
cable from the CDR mechanical unit. (Fig. 2)
d. Remove 2 hexagonal cap nuts marked
e
. (Fig. 1)
e. Remove 4 screws marked
r
, and take out the CDR
mechanical unit. (Fig. 1)
f. Remove the Lid.
g. Remove 4 screws marked
t
, and the Frame/CDR can
be removed. (Fig. 3)
Top Cover
Word Clock Cable
r
IDE Cable
Power Cable
CDR Mechanical Unit
CDR Mechanical Unit
Lid
Fig. 2
Frame/CDR
2. Transportation of CDR Mechanical Unit
a. When transporting the CDR mechanical unit, be sure to install the lens cover to it and put it in the anti-static bag before
packaging it.
IDE cable
a. Do not remove the cable from the female connector by
pulling on the cable.
b. Remove the connector from the female connector by in-
serting the minus driver into the insertion place and hook-
ing the female connector as per fig. A.
Fig. A
A insertion place