5

Caution for Speaker Connection

1.

Turn off the POWER switch.

2.

Remove the cover attachment screw(s) and remove
the protective cover from the speaker terminals.

Screw

3.

After removing approx. 15 mm of insulation from the
ends of the speaker cables, bind the bare ends of the
speaker wires in the corresponding speaker terminals
and tighten the terminals to securely clamp the wires.
Refer to page 3 for speaker porality.

15mm*

*

 Shown actual size.

At this time make sure that the bare ends of the
speaker cables do not extend from the terminals in
such a way that they touch the chassis.

Wire should not 
touch the chassis.

4.

Reattach the protective cover over the speaker
terminals.

• Speaker fuse

The output capacity of your amplifier is very high:
460 W+460 W (8

) in stereo and 1240 W (8

) in

monaural on the C450; 340 W+340 W (8

) in stereo

and 880 W (8

) in monaural on the C320; 160

W+160 W (8

) in stereo and 400 W (8

) in monau-

ral on the C160. Be sure to use a speaker system that
has sufficient input capacity.
If the input capacity of your speaker system is lower
than the rated output of the power amplifier, you can
protect your speakers by connecting a fuse serially
between the speaker and amplifier as shown below.

_

+

_

+

Power amplifier

Speaker system

Fuse

Use the following formula to determine the fuse
capacity according to the speaker’s input capacity.

Po = I R 

 I =   Po/R

2

P0 [W] : Speaker’s continuous input capacity (noise

or RMS)

R [

]

: Speaker’s nominal impedance

I [A]

: Required fuse capacity

ex.)

Speaker’s continuous input capacity : 100 W
Speaker’s impedance : 8

I =   100/8

In this example, the required fuse capacity is calcu-
lated as 3.5 [A].

• Speaker cable

If you use a long speaker cable, use as thick a cable as
possible to prevent deterioration of the damping factor
or power loss inside the cable.

Summary of Contents for C 450

Page 1: ...POWER AMPLIFIER Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucci nes TEMP PROTECTION POWER ON OFF A B CLIP SIGNAL M...

Page 2: ...efficiency drive The EEEngine s energy saver low heat generation design has reduced power consump tion to 50 or less and reduced heat generation to 35 or less in field applications compared to Yamaha...

Page 3: ...th the internal circuitry will void the warranty 5 Make sure power is off before making or removing connections Always turn the power OFF prior to connecting or disconnecting cables This is important...

Page 4: ...otection systems is activated during normal use this indicator lights up and no sound is output The speaker system is actually disconnected from the amplifier outputs when this indicator lights up The...

Page 5: ...on page 4 5 GND terminals This is the grounding screw terminal If hum or noise occurs ground earth the unit via this jack or try connecting it to the chassis of the mixer or preamp etc 1 Volume contr...

Page 6: ...GE MAX OUTPUT 450W 4 STEREO MAX OUTPUT 900W 8 BRIDGE Set to PARALLEL Speaker System 4 min 4 min SPEAKERS CHANNEL B CHANNEL A BRIDGE STEREO STEREO PARALLEL BRIDGE mode connections BRIDGE MAX OUTPUT 450...

Page 7: ...ural on the C450 340 W 340 W 8 in stereo and 880 W 8 in monaural on the C320 160 W 160 W 8 in stereo and 400 W 8 in monau ral on the C160 Be sure to use a speaker system that has sufficient input capa...

Page 8: ...When doing so it is necessary for 35 or more of the entire surface area of a 1U size panel to be open Air circulation will be even better if the top surface of the rack has ventilation openings Ventil...

Page 9: ...en for ventilation Front Air intake Air exhaust Completely open Rear View Side View SPEAKERS CHANNEL B CHANNEL A INPUT CHANNEL B CHANNEL A G G BRIDGE PARALLEL BRIDGE STEREO STEREO BRIDGE CHANNEL B CHA...

Page 10: ...105 dB 104 dB 101 dB Channel Separation Half Power 8 Vol max 65 dB 20 Hz 20 kHz input 600 shunt 75 dB 1 kHz Slew Rate STEREO 30 V sec 8 full swing BRIDGE 50 V sec Sensitivity Vol max Rated Power into...

Page 11: ...PC Limiter Ach Power Amp PC Limiter SPEAKERS BRIDGE PARALLEL CHANNEL A CHANNEL B CHANNEL B CHANNEL A INPUT PROTECTION TEMP Heat Sink Sensor Circuit Protection STEREO PARALLEL BRIDGE G G SIGNAL Dimens...

Page 12: ...nce of at least 4 stereo or 8 bridge Check the ventilation slots and improve the airflow around the amplifier Check the amplifier ventila tion conditions and take appropriate measures to improve airfl...

Reviews: