background image

2

Controls and Functions

Front Panel

TEMP

PROTECTION

POWER

ON       OFF

A

B

CLIP

SIGNAL

1

2

3

4

5

1

POWER switch and indicator
This is the main POWER switch. Press to power ON
the amplifier. Press again to power OFF. The POWER
indicator lights up when the amplifier is powered ON.

2

TEMP indicator
When the temperature of the heat sink exceeds 85
degrees Celsius, this indicator will light red.

3

PROTECTION indicator
This red LED indicator lights up for approximately 3
seconds when the amplifier is powered ON, indicating
that the soft-start protection system is working. No
sound is output during soft-start up. If one of the
protection systems is activated during normal use, this
indicator lights up and no sound is output. The
speaker system is actually disconnected from the
amplifier outputs when this indicator lights up. The
protection systems are activated when overheating
occurs or a DC voltage is present at the amplifier
outputs. If the problem is corrected, the protection
systems deactivate automatically, this indicator goes
out, and normal amplifier operation is resumed.

4

CLIP indicators
These red LED indicators light up when the respective
channel’s output signal distortion exceeds 1% (i.e.
clipping). Output signal clipping is usually due to
excessive input signal levels.

5

SIGNAL indicators
These green LED indicators light up when the
respective channel’s output signal exceeds 2 Vrms.
This is equivalent to 1/2 watt into 8

, 1 W into 4

.

Summary of Contents for C 450

Page 1: ...POWER AMPLIFIER Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucci nes TEMP PROTECTION POWER ON OFF A B CLIP SIGNAL M...

Page 2: ...efficiency drive The EEEngine s energy saver low heat generation design has reduced power consump tion to 50 or less and reduced heat generation to 35 or less in field applications compared to Yamaha...

Page 3: ...th the internal circuitry will void the warranty 5 Make sure power is off before making or removing connections Always turn the power OFF prior to connecting or disconnecting cables This is important...

Page 4: ...otection systems is activated during normal use this indicator lights up and no sound is output The speaker system is actually disconnected from the amplifier outputs when this indicator lights up The...

Page 5: ...on page 4 5 GND terminals This is the grounding screw terminal If hum or noise occurs ground earth the unit via this jack or try connecting it to the chassis of the mixer or preamp etc 1 Volume contr...

Page 6: ...GE MAX OUTPUT 450W 4 STEREO MAX OUTPUT 900W 8 BRIDGE Set to PARALLEL Speaker System 4 min 4 min SPEAKERS CHANNEL B CHANNEL A BRIDGE STEREO STEREO PARALLEL BRIDGE mode connections BRIDGE MAX OUTPUT 450...

Page 7: ...ural on the C450 340 W 340 W 8 in stereo and 880 W 8 in monaural on the C320 160 W 160 W 8 in stereo and 400 W 8 in monau ral on the C160 Be sure to use a speaker system that has sufficient input capa...

Page 8: ...When doing so it is necessary for 35 or more of the entire surface area of a 1U size panel to be open Air circulation will be even better if the top surface of the rack has ventilation openings Ventil...

Page 9: ...en for ventilation Front Air intake Air exhaust Completely open Rear View Side View SPEAKERS CHANNEL B CHANNEL A INPUT CHANNEL B CHANNEL A G G BRIDGE PARALLEL BRIDGE STEREO STEREO BRIDGE CHANNEL B CHA...

Page 10: ...105 dB 104 dB 101 dB Channel Separation Half Power 8 Vol max 65 dB 20 Hz 20 kHz input 600 shunt 75 dB 1 kHz Slew Rate STEREO 30 V sec 8 full swing BRIDGE 50 V sec Sensitivity Vol max Rated Power into...

Page 11: ...PC Limiter Ach Power Amp PC Limiter SPEAKERS BRIDGE PARALLEL CHANNEL A CHANNEL B CHANNEL B CHANNEL A INPUT PROTECTION TEMP Heat Sink Sensor Circuit Protection STEREO PARALLEL BRIDGE G G SIGNAL Dimens...

Page 12: ...nce of at least 4 stereo or 8 bridge Check the ventilation slots and improve the airflow around the amplifier Check the amplifier ventila tion conditions and take appropriate measures to improve airfl...