36
RX-V1
065/HTR-6280/
AX-V1
065
RX-V1065/HTR-6280/AX-V1065
●
Display provided when Self-Diagnostic
Function started
The display is as described below depending on the
situation when the last time the power to this unit is turned
off.
1. When the power is turned off by usual operation:
The FL display of this unit displays “NO PROTECT”
then the main menu (sub-menu “1. ANALOG BYPAS”
of main menu 1 BYPASS) a few seconds later.
2. When the protection function worked to turn off
the power:
The FL display of this unit displays the data of
protection function which worked at that time then the
main menu (sub-menu “1. ANALOG BYPAS” of main
menu 1 BYPASS) a few seconds later.
Note: At that time if you reactivate the self-diagnostic
function after turning off the power once by
pressing the “MAIN ZONE ON/OFF” key, “NO
PROTECT” will be displayed because that
situation is equal to “1. When the power is
turned off by usual operation:” described above.
However the protection function history is
stored in memory with a backup.
For details,
refer to main menu 21 PROTECTION HISTORY.
2-1. When the protection function worked due to
excess current.
● ダイアグ起動時の表示
最後に本機の電源が切れたときの状況により、下記のよ
うに表示されます。
1. 通常の操作で電源を切った場合:
本機の FL ディスプレイに “NO PROTECT” が表示さ
れます。数秒後、メインメニュー 1 BYPASS のサブメ
ニュー “1. ANALOG BYPAS” が表示されます。
2. プロテクションが働いて電源が切れた場合:
本機の FL ディスプレイにそのときに働いたプロテ
クションの情報が表示されます。数秒後、メインメ
ニュー 1 BYPASS のサブメニュー “1. ANALOG BYPAS”
が表示されます。
注) このときに “STANDBY/ON” キーを押して一旦電
源を切った後にダイアグを再起動すると、上述
の「1. 通常の操作で電源を切った場合」に相当
するので、“NO PROTECT” が表示されます。
ただし、プロテクションの履歴はメモリーにバッ
クアップして記憶されます。詳細は、メインメ
ニュー 21 PROTECTION HISTORY を参照してくだ
さい。
2-1. 過電流によりプロテクションが働いた場合
N O P R O T E C T
1 . A N A L O G B Y P A S
原因:
パワーアンプに過電流が流れた。
補足:
パワートランジスタの電流を検出していますので、
電流検出トランジスタをチェックすれば異常チャ
ンネルが特定できます。
異常状態のまま電源を入れると、瞬時にプロテクション
が働き、すぐに電源が切れます。
Cause:
An excessive current flowed through the power
amplifier.
Supplementary information:
As current of the power
amplifier is detected, the abnormal channel can be
identified by checking the current detect transistor.
Turning on the power without correcting the abnormality
will cause the protection function to work immediately and
the power supply will instantly be shut off.
After a few seconds /
数秒後
Main menu display /
メインメニュー表示
Opening message /
オープニング表示
AD value when the protection function is working
電圧の A/D 変換値
P R I P R T : x x x
Summary of Contents for AX-V1065
Page 5: ...5 RX V1065 HTR 6280 AX V1065 RX V1065 HTR 6280 AX V1065 AX V1065 J model ...
Page 9: ...9 RX V1065 HTR 6280 AX V1065 RX V1065 HTR 6280 AX V1065 HTR 6280 C model AX V1065 J model ...
Page 162: ...RX V1065 HTR 6280 AX V1065 162 ...
Page 163: ...163 RX V1065 HTR 6280 AX V1065 RX V1065 HTR 6280 AX V1065 ...
Page 164: ...164 RX V1065 HTR 6280 AX V1065 RX V1065 HTR 6280 AX V1065 ...
Page 165: ...165 RX V1065 HTR 6280 AX V1065 RX V1065 HTR 6280 AX V1065 MEMO ...
Page 166: ...RX V1065 HTR 6280 AX V1065 ...