ERROR MESSAGES
AO8
27
If an error occurs in the connection to the DSP1D, or if the unit does not lock to the wordclock signal, one of the following
error indications appears.
ERROR MESSAGE
DESCRIPTION
The AO8 is connected to the INPUT connector of the DSP1D/DSP1D-EX. Connect the AO8 to the
OUTPUT connector.
A cable is disconnected from the INPUT A, B, or C connector on the rear panel, or the connection is
made incorrectly. If the connection is proper, replace the cable.
The unit does not lock to the wordclock signal.
The control signal is not being received correctly.
(two dots and the ID number of the OUTPUT connector on the DSP1D/DSP1D-EX)
Illuminating dots means that the AO8 is con-nected in Mirror mode from the DSP1D/DSP1D-EX.
If “.x .” lights up continuously during Mirror mode operation, the INPUT SELECTOR switch setting
matches the setting controlled from the CS1D and the system is operating normally.
If the control signal from the CS1D has changed the setting during Mirror mode operation and it
does not match the INPUT SELECTOR switch setting any more, this indicator changes in the
following order.
“
” means that the control signal from the CS1D has changed the setting to “A”
“
” means that the control signal from the CS1D has changed the setting to “B.”
During this time period, you can connect or disconnect the cable from the unselected output connector.
If you set the INPUT SELECTOR switch so that it matches the setting made via the control signal
from the CS1D, “
” lights up continuously.
“. .”
“ .x.”
“. .”
“
”( or “ ”)