ELEC
8-31
COOLING SYSTEM
MEETS
SPECIFICATION
MEETS
SPECIFICATION
Pocket tester :
90890-03112
Fuse defect
➞
Replace.
2. Battery
• Check the condition of the battery.
Refer to “BATTERY INSPECTION” in
CHAPTER 3.
Battery voltage :
12.8 V or more at 20
°
C (68
°
F)
TROUBLESHOOTING
WATER TEMPERATURE METER DOES NOT MOVE, WHEN THE ENGINE IS WARM.
NOTE :
Remove the following parts before proceeding with the troubleshooting:
• Side covers and footrest board
• Handlebar cover
For accurate troubleshooting use the following special tools :
1. Fuse
• Remove the fuse.
• Connect the pocket tester (
Ω
x 1) to the fuse.
• Check the fuse for continuity.
Refer to “FUSE INSPECTION” in Chapter 3.
3. Main switch
• Disconnect the main switch from the wire
harness.
• Turn the main switch to “
✱
”.
• Check for continuity between :
Red
Q
and Gray
E
• Turn the main switch to “ON”.
• Check for continuity between :
Red
Q
and Brown
W
DOES NOT MEET SPECIFICATION
Main switch defect
➞
Replace.
DOES NOT MEET SPECIFICATION
• Clean battery terminals.
• Charge or replace the battery.
NO CONTINUITY
R
B
BW
BW
BW
BW
LOCK
LOCK
ON
ON
CHECK
CHECK
OFF
OFF
Br
Br Gy
Gy
Br
Br
Gy
Gy
B
R
햲
햴
햳
CONTINUITY