4
3.4 Installation of siphon pump
(Using a wall bracket)
1) Attach a wall bracket (sold separately) or a panel
unit (sold separately) to the pump. Or secure the
pump to a mounting.
2) Connect a suction hose assembly (sold
separately) to the pump.
(
Fig. 6
)
3.5 Installation of silencer
CAUTION
- Each connection is capped. Remove the caps all.
- Wrap sealing tape around the silencer thread to prevent leakage.
Attach the silencer to the pump and secure it using a tool. (Fig. 7)
Wrap sealing tape around the silencer thread to prevent leakage.
3.6 Connecting
the ground wire
WARNING
- Make ground connection when working with flammable material or in explosive atmosphere. Rapid
pumping of material can result in static electrical charge. Also, be sure to provide proper ventilation
where a flammable atmosphere may exist.
1) When installing the pump, be sure to connect the ground wire at the
specified position. For the specified position for connecting the ground
wire, see [1. Names of parts and materials].(Fig. 8)
2) Also connect ground wires to peripheral equipment and piping.
3) Use
2.0mm
2
minimum ground wire.
Fig. 7
Fig. 8 Position for connecting
the ground wire
Fig. 6