background image

 

PROBLEM

POSSIBLE CAUSE

REMEDY

Compressor is off.

Turn on compressor.

Valve on air piping is closed.

Open valve.

Air pressure setting is under 0.2MPa.

Set air pressure to 0.2MPa or above.

Valve on material outlet is closed.

Open valve.

Frost occurs inside silencer.

Use dry air.

O ring on sliding part of air piston is worn out.
(Air leak occurs from silencer.)

Block (773210) and ball (686271) in valve body (804815) are worn out.
Any parts (e.g. spring, pin) used in switching system in valve body (804815) or
air motor (804814 / 804856) are damaged.

Air leak from air

motor

- Fasteners are loose.
- O rings and packings are worn out.

- Retighten loose parts.
- Replace worn part.

Air leak from

silencer during

shutdown

- Foreign object is caught between block (773210) and valve seat (716246) in
  valve body (804815).
- Seating part is worn out.

- Remove foreign object.
- Replace worn part.

Pump doesn’t run

and air leaks from

silencer

- Foreign object is caught between spindle (716299) and valve switcher
  (832996) in air motor (804814 / 804856).
- There exists damage that prevents sliding movement of parts below.

- Remove foreign object.
- Replace damaged part.

Pump doesn’t draw

material at first time

of operation

Pump operating speed is so fast that lower pump suction cannot keep up with
pump movement. (Valve inside lower pump is not working well.)

Set pump speed to 5-8 sec. per cycle until
material is pumped out.

If upward movement of plunger is faster,
- seat surface of piston valve is defective (wear of seat surface, inclusion of
  foreign  material) or,
- packings are damaged.

If downward movement of plunger is faster,
- seat surface of foot valve is defective (wear of seat surface, inclusion of foreign
  material),
- packings are damaged, or
- shovel rod is bent.

If downward movement of plunger is faster, operating speed is so fast that lower
pump suction cannot keep up with pump movement. (Vacuum is caused inside
lower pump.)

Decrease air pressure until material
comes out. (This pressure is the upper
limit of normal operating pressure.)

Connecting rod connecting air motor and lower pump is completely separated
from air motor. (In this case, parts inside of lower pump may be damaged.)

Inspect inside lower pump first, then
replace damaged part, and retighten each
part.

Leak occurs in delivery pipe.
Leak occurs in lower pump (connections are loosened or o ring, backup ring, or
packing is damaged).

Material leak from

lower pump

- Fasteners are loose.
- O ring, backup ring or packing is damaged.

- Retighten loosened parts.
- Replace damaged part.

Material contains

air bubbles even

after bleeding

- Fasteners are loosened.
- O ring or backup ring is damaged.

- Retighten loosened parts.
- Replace damaged part.

- Retighten loose parts.
- Replace damaged part.

Pump doesn’t stop

- Remove foreign object.
- Replace damaged part.

Pump doesn’t run

Replace worn out or damaged part.

Material cannot be

pumped out

5.2 Troubleshooting 

If you suspect that you have a problem with your product, consult the table below for some common problems 
and their solutions. Contact the retail store where you purchased your product or our business office if all else 
fails. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 40 Series

Page 1: ...SR140P50 P MODEL No 854559 50 1 SR140P25 D MODEL No 854560 25 1 SR140P38 D MODEL No 854561 38 1 SR140P50 D MODEL No 854562 50 1 SR125D13 MODEL No 854664 13 1 WARNING Prior to operating this pump be s...

Page 2: ...ings and Cautions To use this product safely be sure to observe the contents of the following description In this manual warnings and cautions are indicated by using symbols These symbols are intended...

Page 3: ...erty damage Be sure to use the unit in accordance with the specifications described in 7 Specifications in this manual Installation and piping Ground connection Make ground connection to pump and peri...

Page 4: ...or breakage Do not plumb directly Do not connect the material outlet and piping directly Attach a flexible tube like a hose to connect the pump to the piping The pump if connected directly to the pipi...

Page 5: ...Connecting suction piping 4 3 6 Discharge piping 4 3 7 Air piping 4 3 8 Preparation for use 4 3 9 Connecting the ground wire 5 4 Operating Method 4 1 Description of valve 5 4 2 Solvent cup 5 4 3 Filli...

Page 6: ...are loose The nylon tube and the silencer are detached from the pump in the packaging due to the shipping conditions 2 Operating principle Yamada s air powered pumps employ reciprocating motion syste...

Page 7: ...ion Use a stopper caster wheel with a brake or other locking device to prevent a mount from moving due to reciprocating pump vibration Before installing the pump verify that the shovel at the bottom i...

Page 8: ...ng as deeply as possible After the installation please make sure that the nylon tube is firmly connected by lightly pulling it 3 3 Installation of silencer CAUTION Each connection is capped Remove the...

Page 9: ...material outlet 2 Connect the other end of the hose to a delivery pipeline Attach a valve at the connection between the hose and the piping for maintenance and keep it closed until unit installation i...

Page 10: ...e the pump only as necessary Avoid allowing the pump to run dry as much as possible The life expectancy of packings will be reduced The pump runs dry when a container becomes empty Stop the pump immed...

Page 11: ...al from the outlet Once the air in the piping is released completely close the air valve for the pump and set the pump air regulator to 0MPa The pump is now ready for operation 2 Adjust the pump air r...

Page 12: ...ng pump operation and There is no abrasion or deterioration apparently in each part of the pump Lubricate pump Lubricate pump according to the following procedure Close the air valve for the pump and...

Page 13: ...ve is defective wear of seat surface inclusion of foreign material or packings are damaged If downward movement of plunger is faster seat surface of foot valve is defective wear of seat surface inclus...

Page 14: ...804815 716246 Valve seat 1 per unit 10 million cycles Block 1 per unit 10 million cycles Spring 1 per unit 10 million cycles Ball 1 per unit 10 million cycles O ring 1 per unit 5 million cycles O ring...

Page 15: ...nal injury or property damage Pump 10 years Standard Conditions of Use SR140P25 SR140P38 SR140P50 SR125D13 Application Season Temperature Material being pumped Supply air pressure Daily Amount of Mate...

Page 16: ...1 632059 3 Slit pin 5 716288 Joint 1 6 716289 Connecting rod 1 7 716286 716290 Stud 3 8 631918 Wave spring washer 3 9 627045 Nut 3 10 804816 804817 804818 804816 804817 804818 Lower pump assembly 1 1...

Page 17: ...1 2 716409 Bushing 1 3 700350 Cap nut 1 4 632059 Slit pin 3 5 716288 Joint 1 6 716597 Connecting rod 1 7 716290 Stud 3 8 631918 Wave spring washer 3 9 627045 Nut 3 10 804956 Lower pump assembly 1 11 7...

Page 18: ...7 640132 O ring 1 10 38 716309 Foot valve housing 1 10 39 640015 O ring 2 10 40 685617 Pin 1 10 41 640020 O ring 1 10 42 715260 Piston body 1 10 43 685618 U packing 2 10 44 685619 Backup ring 2 10 45...

Page 19: ...t 1 10 37 640132 O ring 1 10 38 716316 Foot valve housing 1 10 39 686305 O ring 2 10 40 632544 632543 Pin 1 10 41 640016 640015 O ring 1 10 42 715568 715576 Piston body 1 10 43 685787 685792 U packing...

Page 20: ...valve housing 1 10 15 640135 O ring 2 10 16 701542 Stopper 1 10 17 713550 Foot valve 1 10 18 701538 Shovel rod 1 10 19 701539 Shovel 1 10 20 631916 Wave spring washer 1 10 21 627012 Nut 1 10 22 83301...

Page 21: ...nd drum pump respectively 3 Measurement method of A weighted sound pressure level is based on ISO 1996 4 Measurement method of A weighted sound power level is based on ISO 3744 0 2 0 7 MPa Rc3 8 Equip...

Page 22: ...NOTE Avoid continuous operation if a desired discharge volume is in the shaded area in the right side of each figure SR140P50 Performance curve SR140P25 Performance curve SR140P38 Performance curve SR...

Page 23: ...cause corrosion inflation or dissolution of the component parts of the product 4 Irregularity arising from repair made by other than by our firm our regional office dealer or authorized service perso...

Page 24: ...8504 Japan PHONE 81 0 3 3777 0241 FAX 81 0 3 3777 0584 E mail intl yamadacorp co jp Web www yamadacorp co jp YAMADA THAILAND CO LTD 41 79 Moo 6 Bangcha long Bangplee Sumutprakarn10540 Thailand PHONE 6...

Reviews: