80-9470-0330-000 (01-13)
ALARM FUNCTION AS SHIPPED
1)
Upon arming, LED will flash
AMBER
and the device will allow egress without triggering alarm for 7 seconds.
2)
After 7 seconds, alarm will chirp one time and the device will be
ARMED.
The LED will flash
RED
every 30 seconds, indicating the device is
ARMED.
3)
Once the device is
ARMED
, egress will result in an alarm sound that will stop only when the device is
RESET
by
key or remote.
4) Low Battery Indicator
- Alarm will chirp every 10 seconds, indicating battery needs to be replaced.
• Alarm PC Board has Dip Switches DS-1, 2, 3, 4, and 5 factory preset per Tables 1, 2, and 3 shown below.
• Dip Switch DS-6 is for “hard wire”configurations and setting does not affect stand-alone battery operation.
REX and Passage Time Delay
TABLE 1
DS-1
DS-2
Timer Delay
*Off
*Off
7 Seconds
Off
On
10 Seconds
On
Off
15 Seconds
On
On
20 Seconds
Automatic Alarm Reset
TABLE 2
DS-3
DS-4
Reset Time
Off
Off
2 Minutes
Off
On
5 Minutes
On
Off
10 Minutes
*On
*On
No Auto Reset
every 30 seconds instead of
RED
to indicate a violation
has occurred.
Armed and Violation LED Color Selection
TABLE 3
Device is shipped standard, per Table 3, so that
RED LED
flashes every 30 seconds when device is
ARMED
, and
flashes
GREEN
every 30 seconds under auto reset, when
door has been violated.
When the device is initially
ARMED
by key, the
LED
will flash
AMBER
and allow egress for a time defined
in Table 1.
Passage
DS-5
Armed
LED Color
Armed Violation
LED Color
Off
On
Red
Green
Amber
Factory Preset
Amber
Green
Red
NOTES:
J1
J2
J4
ON
J3
1
2
3
4
5
6
ON
1
2
3
4
5
6
Dip Switch Settings
Enlarged View
Black
Battery plugs in place with polarity
connected as shown
(+)
(—)
Battery
Bracket
* The unit is shipped with power disconnected, attach battery connector as shown below.
The alarm can be set so that it will reset itself after a
violation has occurred per Table 2. If the device
automatically resets, the indicator light will flash
GREEN
When the unit is hard wired, DS-6 must be in the “On” position for remote monitoring thru connector J3.
5