1. Frame and Door Preparation

Frame
Edge

Horizontal
Reference
Line

L

C

Out-swinging Door

In-swinging Door 

DO

OR

DOOR

Frame

Frame

1.  

For installation on an In-swinging Door, mark a

     Vertical Reference Line 1-15/16"(50mm) off of the
     Frame Edge, also decide the vertical placement and
     mark a Horizontal Reference Line. Align template
     as shown with Vertical and Horizontal Reference Lines. 

2.  

Use a center punch to mark door for

     (2) .144"(3.7mm) Dia. (#27 Drill) mounting holes
     for the Device Mounting Base (Shown Below). 

3.  

Use a center punch to mark frame for (2) .099"(2.5mm) Dia.

     (#39 Drill) holes for the Magnet (Shown Below).

    

4.  

If outside Cylinder Control Option is to be used,

     bore a 1-1/4"(32mm) Dia. Hole thru door.

 Fig. 2 ‘B’ Hole

5.  

For Hardwire option requiring door preparation, mark and

     bore a 1"(25mm) Dia. Hole to required depth. 

Fig. 2 ‘C’ Hole

6.  

Install Magnet to door frame with (2) #4 screws supplied.

1.  

For installation on an Out-swinging Door,

     mark a Vertical Reference Line 2-3/16"(56mm)
     off of the Frame Stop, also decide the vertical
     placement on the door and mark a Horizontal
     Reference Line. Fold template as shown and
     align with Vertical and Horizontal Reference Lines. 

2.  

Use a center punch to mark door for

     (2) .144"(3.7mm) Dia. (#27 Drill) mounting holes
     for the Device Mounting Base (Shown Below).

3.  

Use a center punch to mark frame for

     (2) .099"(2.5mm) Dia. (#39 Drill) holes for the Magnet
     (Shown Below).

4.  

If outside Cylinder Control Option is to be used,

     bore a 1-1/4"(32mm) Dia. Hole thru door. 

Fig. 1 ‘B’ Hole

5.  

For Hardwire option requiring door preparation, mark and

     bore a 1"(25mm) Dia. Hole to required depth. 

Fig. 1 ‘C’

     Hole

6.  

Install Magnet to door frame with (2) #4 screws supplied.

        
           

Vertical
Reference
Line

Vertical
Reference
Line

Horizontal
Reference
Line

Figure 2

Figure 1

C

B

C

B

Arrows on the magnet face toward the  
alarm housing and away from the door.

!

Arrows on the magnet face toward the
alarm housing and away from the door.

!

2

Summary of Contents for SDA16

Page 1: ...SDA16 Stand Alone Alarm Device Installation Instructions An ASSA ABLOY Group brand 80 9470 0330 000 01 13 EMERGENCY EXIT ALARM WILL SOUND ...

Page 2: ...Install Magnet to door frame with 2 4 screws supplied 1 For installation on an Out swinging Door mark a Vertical Reference Line 2 3 16 56mm off of the Frame Stop also decide the vertical placement on the door and mark a Horizontal Reference Line Fold template as shown and align with Vertical and Horizontal Reference Lines 2 Use a center punch to mark door for 2 144 3 7mm Dia 27 Drill mounting hole...

Page 3: ...l secure NOTE Actuator should be free to rotate by installing in position shown Orient Arrow towards Door Edge 1 Remove 2 screws retaining the magnet sensor and set components aside 2 Remove 2 screws retaining the Tamper Switch and exchange locations of both components See Figure 5 3 Reattach components with the screws NOTE a The arrow on the magnet sensor should face outward towards the edge of t...

Page 4: ...itor both doors TIP Attach unit to a wall stud 1c Wall Mounting to a single Gang Box Attach the Mounting Base through holes A and X using standard gang box screws as shown in Figure 8 Gang Box screws not provided Attach Alarm Housing per section 4 2 4 3 Standard Installation Hole D Hole D Hole X Gang Box Only Hole A 1 After preparing the door attach the Mounting Base to door through holes A D usin...

Page 5: ...S 4 Reset Time Off Off 2 Minutes Off On 5 Minutes On Off 10 Minutes On On No Auto Reset every 30 seconds instead of RED to indicate a violation has occurred Armed and Violation LED Color Selection TABLE 3 Device is shipped standard per Table 3 so that RED LED flashes every 30 seconds when device is ARMED and flashes GREEN every 30 seconds under auto reset when door has been violated When the devic...

Page 6: ...of DS 5 Dip Switch OFF for RED ARMED indicator ON for GREEN ARMED indicator Solution Yale is a registered trademark of Yale Security Inc an ASSA ABLOY Group company Other products brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only These materials are protected under U S copyright laws All contents current at time of publi...

Page 7: ...5 16 50 Magnet and Cylinder located on same centerline Arrow on Magnet oriented towards Alarm Housing Assembly L C DOOR Locate off of edge to clear swing of door L C CAUTION Office copiers and facsimile mach ines may change the size of a drawing and make the template inaccurate to use as a door marker If this is not the original template packed with the trim use only the holes on the door do not u...

Page 8: ...stall Hardwire Option Std Install x Outside Cylinder FUNCTION A D E A C D E A B D E Dia 27 Drill 144 4 1 9 16 40 3 3 4 95 3 8 10 2x 099 3 Dia 39 Drill 13 16 21 1 21 32 42 2 3 16 56 2 3 16 56 1 25 Dia 1 1 4 32 Dia Thru 13 16 21 Dia 27 Drill 144 4 13 16 21 3 8 10 099 3 Dia 39 Drill 2x 1 21 32 42 2 3 16 56 3 16 5 Ref 1 16 2 Magnet and Cylinder located on same centerline Arrow on Magnet oriented away ...