Optional accessories and consumable parts
KIT
# Part
* CAUTION: When using this CFM
reduction kit, the maximum BTU use for this
hood is 78 KBTU’s
8”- 10” Long Chimney Extension
ACC01935
9” – 13” Long Chimney Extension
ACC02785
CFM Reduction Kit
ACC0185099*
Kit No Blower External
KIT0179547
Kit No Blower In Line
KIT0179549
Ducting options
Closely follow the instructions set out in this manual.
All responsability, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined.
Ducting version
The hood is equipped with an 8” (20.3 cm) round transition for discharge of fumes to the outside.
Roof Venting
Wall Venting
A
B
A
C
B
A. Roof cap
B. 8” (20.3 cm) round vent
A. Wall cap
B. 8” (20.3 cm) round vent
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or
stud must be cut, then a supporting frame must be
constructed.
Fittings material is provided to secure the hood to most types of
walls/ceilings.
However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Recommended installation height:
Hood installation height above cooktop is the users preference.
The lower the hood is above the cooktop, the more efficient the
capturing of cooking odors, grease and smoke.
CAUTION
For gas cooktop & range installations: Mount the hood so the
bottom is at least 30” (76.2 cm) above the cooking surface.
For electric/induction cooktop & range installations: Mount the
hood so the bottom is at least 24” (61 cm) above the cooking
surface.
There is no maximum mounting height, however, we recommend
mounting the hood no greater than 36” (91.4 cm) above the
cooking surface. For every inch (2.54 cm) above 36” (91.4 cm),
fume and moisture capture efficiency diminishes at an increasing
rate and may not deliver an acceptable level of ventilating
performance.
This hood is intended for household use.
PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC
APPLICATION. Check your ceiling height and hood height
before selecting your hood.