background image

7

Adding accessories (if you purchased extra accessories)

All accessories in the kit are linked to the control box. If you purchased extra accessories (or for 
some reason the accessories are deleted), please do the following:

1

Learn

Power

Battery

<On Off>

Press and hold the learn button for at least 3 seconds.

Led 1 will now flash and beep to indicate that you have entered learn mode

2

3

ale

Y

Learn

button

ale

Y

Learn

button

Learn

button

ale

Y

1 2

3

6

5

4
7 8 9

0

Learn button:

Press 8 and 9 

together

Learn

button

Learn

button

ale

Y

Learn Button

Press & hold 
for 3 seconds

One by one, press the learn button on the accessories. The 
control box will beep every time a new device is registered 

Exit Learn Mode:

Press and hold the control box learn button for at least 3 seconds. 
The LED should now stop flashing. Proceed to installation. 

For the following accessories, please hold the learn button for 10 
seconds before releasing to learn.

Learn button

Hold for 10 seconds

Learn button

Hold for 10 seconds

18.

8

c

42

ah

%

Learn button

Hold for 10 seconds

Learn button

Hold for 10 seconds

EF-PC

EF-RS

EF-PS

EF-PVC

HSA6020

HSA6010

HSA3045

HSA6060

HSA6080

         HSA3070

HSA6050

Summary of Contents for HSA6092

Page 1: ...l result in an alarm Display extreme caution when using ladders or steps please follow manufacturer s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines w...

Page 2: ...he System Extend the system in the future to increase your security or as your needs change For example add extra PIR detectors and extra door window contacts Choosing Location To minimise interferenc...

Page 3: ...this door or window PIR Movement Detector or PIR Camera Mount in a position such that an intruder would normally move across the PIRs field of view Height should be between 1 9 and 2 metres above flo...

Page 4: ...per switch unnecessarily 1 Remove the cover by unscrewing the single screw located on the lid Power switch to ON position 1 Pull out the plastic pull tab on the back of the PIR This will activate the...

Page 5: ...N21 battery as shown and replace battery cover Switch to on Help button accessory Remove the cover by loosening the fixing screw and insert the 12V battery supplied as shown Please ensure you observe...

Page 6: ...own Once you have received BOTH the authentication email and SMS click on the email link i Select New user click here i Enter your details Panel MAC can be found on the Control box s sticker Close app...

Page 7: ...ress 8 and 9 together Learn button Learn button ale Y Learn Button Press hold for 3 seconds One by one press the learn button on the accessories The control box will beep every time a new device is re...

Page 8: ...will show up on the last screen see above The radio signal strength is shown by a number under the device name This number ranges from 1 to 9 strongest Where possible please ensure devices show 3 or a...

Page 9: ...hat some surface or environment i e exposure to Sunlight may be unsuitable for this mounting method Please use screw mounting in these cases Mounting using screws and wall plugs Loosen the bottom scre...

Page 10: ...alarm is triggered the system will send an email push notification iOS only and SMS to alert the owner The network traffic condition will determine how quickly the user is alerted There may be notice...

Page 11: ...e system However the person inside the house can move freely around without triggering the alarm Home mode is usually used to protect the ground floor when you are upstairs in bed To enable home arm y...

Page 12: ...oldest images videos are automatically deleted to make space Users are advised to delete unwanted images videos Adding alert email SMS You can add delete email and SMS phone numbers for alert during a...

Page 13: ...known as slave mode 4 Quit test mode by pressing the disarm key twice The keypad code and mode setting has been completed The keypad will now use the same pincode that is set for the control panel un...

Page 14: ...fire alarm with a radio fire alarm signal to the control unit Testing Smoke detector testing should be done on a regular monthly basis Pressing the test button will make the LED flash the audible soun...

Page 15: ...because any other battery can cause problems with the operation of the system Typical life of batteries is two years or more Ensure the correct steps are taken when changing batteries in tamper protec...

Page 16: ...number key and check that the LED lights If the LED lights the new battery installation is successful screw keypad back on and the battery change is complete Help Button Battery Change When the batter...

Page 17: ...nsitive walking directly towards it PIR gives false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check...

Page 18: ...ual edge sequential pulse count with pulse length discrimination Radio 433MHz AM Power supply 4 5V 3 x AAA alkaline cells 2 years typical domestic service life without supervision Movement detection r...

Page 19: ...ngland WV13 3PW John Ward Director 17 Model HSA3400 HSA3020 HSA3060 HSA3010 HSA3050 HSA3045 HSA3080 HSA3030 HSA3070 EN 300 220 1 V2 3 1 2010 EN 300 220 2 V2 3 1 2010 EN 301 489 1 V1 8 1 2008 EN 301 48...

Page 20: ...to cosmetic or appearance damage 3 Claiming on the Warranty a i If you purchased a YALE branded product from a retailer or other reseller as opposed to direct from SECURITY MERCHANTS and wish to clai...

Page 21: ...any other expenses of claiming on the Warranty c If products are returned to SECURITY MERCHANTS for which in SECURITY MERCHANTS s reasonable opinion the Warranty does not apply the products will be re...

Page 22: ...he products defaced or removed p the removal refitment or replacement of SECURITY MERCHANTS s YALE branded products or associated charges or q personal injury property damage direct indirect special o...

Page 23: ...3 years typical domestic service life 0560 18 All devices EMC Tested to ETS 300 683 Radio Components tested to EN 300 220 1 Environmental conditions 10 C to 40 C relative humidity 70 non condensing fo...

Reviews: