Yale HSA3800 Installation, Programming, Operating Download Page 27

27

Specifications

All devices

EMC

Tested to EN 300 220-1 and ETS

300 683

Environmental conditions

-10°C to 40°C, relative humidity

70% non-condensing for all units
except the external siren. Siren: -20°C
to 50°C, relative humidity 95% non-
condensing

Radio operational range

30m in a typical domestic

installation

Can vary depending on building

construction and RF environment.

Housings 

ABS

Control unit

Keys

Scrolls display downwards

Scrolls display upwards

c

Program button, telephone
dialler

b

Phone number pause

a

When in programming
mode, clears the screen or
return to previous menu;
back space for telephone
numbers

Device codes

DC

Door/window contact

PIR

PIR movement detector

SD

Smoke detector

RC

Keyfob remote control

KP

Keypad remote control

WTR Help watch

Control unit illumination

Display is back lit

when the unit is mains powered.

Housing 

ABS

Siren Output 

95dBA sound pressure @

1m minimum

Zones 

20 radio devices

Radio system 

433.92MHz AM Integral

transmitter and super heterodyne
receiver with jamming detection

Power supply 

Plug top adaptor type, input

230VAC 50Hz, output 9VDC, 500ma,
tested to EN 60 950

Rechargeable battery 

Nickel cadmium

7.2V, 600mah, charge time 72h,
standby duration 8h

Telephone interface 

Tested to TBR 21.

Hands free vox operated, 6
programmable numbers with 4
different pre-recorded messages
REN rating 1

Siren

Siren output 

104dBA sound pressure @

1m minimum

Radio 

433.92MHz AM super heterodyne

receiver with jamming detection 

Power supply 

6V, 4 x D alkaline cells. 3

years minimum typical service life 

PIR movement detector

Alarm processing 

Microprocessor

controlled dual edge sequential pulse
count with pulse length discrimination

Radio 

433.92MHz AM transmitter 

Power supply 

4.5V, 3 x AA alkaline cells.

3 years minimum typical domestic
service life, 1-minute sleep timer 

Movement detection range 

15m, 110°

Door/window contact

Radio 

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

3V, 2 x AAA alkaline cells. 3

years minimum typical domestic
service life @ 50 activations a day

Smoke detector

Radio 

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

6V, 4 x AAA alkaline cells. 3

years minimum typical domestic
service life

Keyfob remote control

Radio 

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

12V 23A/MN21 alkaline

miniature "lighter" battery. 3 years
minimum typical domestic service life 

Keypad remote control

Radio 

Microprocessor controlled

433.92MHz AM transmitter 

Power supply 

9V alkaline PP3. 3 years

minimum typical domestic service life

Help button

EMC

Tested to EN 300 220-1 and ETS

300 683

Environmental conditions 

-10°C to

40°C, relative humidity 70% non-
condensing

Radio operational range 

30m in a

typical domestic installation. Can vary
depending on building construction and
RF environment

Radio 

Microprocessor controlled

433.92MHz AM transmitter

Power supply 

12V 23A/MN21 alkaline

miniature “lighter battery”. 3 years
typical domestic service life

Model:

HSA3800

HSA3020

HSA3060

HSA3010

HSA3050

HSA3045

HSA3080

HSA3030

HSA3070

Downloaded from www.ukpanels.com

Summary of Contents for HSA3800

Page 1: ...A3800 Telecommunicating control panel alarm system Installation Programming Operating Keep in a handy place for reference and for future maintenance Helpline 01902 635998 Downloaded from www ukpanels com ...

Page 2: ...re in the world This innovative feature allows the kind of flexibility and control we have come to expect in this day and age When accessed via telephone the system will only work with your PIN code It is important to ensure that you keep this number secure Home and away arming In addition to fully arming the system the HSA3800 also allows you to home arm The home mode allows you to arm the system...

Page 3: ...es Carton contents Control unit and mounting base External siren Dummy siren 2 x PIR 2 x Door contact 2 x Door contact magnet 2 metre 500mA 9V power adaptor 3 metre telephone cable 2 way telephone adaptor 4 x 1 5V AAA alkaline cells 6 x 1 5V AA alkaline cells 4 x 1 5V D alkaline cells 2 x Large adhesive pad 2 x Small adhesive pad 4 x small wall plugs 12 x medium wall plugs 8 x large wall plugs 8 x...

Page 4: ... arming mode the sensors for these areas should be programmed to home omit and the sensors activated on the path to access the control unit should be to be set to home delay as explained in Further programming page 16 Operating range All devices must be within 30 metres of the control unit and must not be mounted on or near large metal objects Avoid obvious sources of electrical interference such ...

Page 5: ...directly facing a window Do not point the PIR at a door protected by a door window contact Keyfob remote control accessory Can be used inside or outside the property and can be kept on your keyring Door Window contact Select a door that will be the main point of entry and exit usually your front door Mount as high as possible Do not aim a PIR at this door or window Siren Choose a position on an ex...

Page 6: ... all the parts onto a table top The easiest way to get to know the system and get it up and running quickly is to get all the devices and accessories programmed on a table top before locating and mounting them 2 Siren WARNING The siren is very loud be prepared Take care not to activate the siren unnecessarily 1 Remove the cover by unscrewing the single screw located at the bottom 2 Remove the cove...

Page 7: ...as shown The Tx LED will flash briefly while components initialise Smoke detector accessory Remove the cover and insert the four AAA batteries as shown Keyfob remote control accessory Slide off the battery cover insert the 23A MN21 battery as shown and replace cover Switch to on Tamper switch Jumper switch Learn Test button Tamper switch Jumper switch Extension terminals Magnet Learn Test button L...

Page 8: ...ic system up and running Do not mount at this stage Control unit When power is connected a long beep will sound Alarm On will be displayed This indicates that the system is armed Before you can deactivate the alarm or enter any information into the system you must enter a PIN code This is factory set to 0000 Disarm 1 Key 0 Enter Code is displayed 2 Key in 000 to complete the factory set code 3 Pre...

Page 9: ...ompartment 1 Lift off jumper number 1 and park it The siren will beep and flash The siren is now in learn mode 2 Lift off jumper 5 and park it This must be left in the off position permanently If jumper 3 and jumper 4 are removed during the learning in process the siren will only be activated for 1 second if accidently activated and is useful for testing Ensure the jumpers are placed into the posi...

Page 10: ...n for the programmed period If the tamper condition persists the siren will sound a series of five pips either every time the system is armed or when the tamper is enabled to indicate the condition Confirm Programming The siren can be programmed to produce additional confirmation beeps to tell you when the system is armed and disarmed from outside the premises One beep for armed or home armed two ...

Page 11: ...y apply to the back of the device Next remove the other cover and firmly press the item onto the desired location Do not use the adhesive pad method of installation on a surface with peeling or cracked paint or on a rough surface Screw mounting Remove the front of the device and if necessary break through the appropriate knockout where the plastic is thinner Using the holes as a template drill hol...

Page 12: ...tted at the same instant when entering cancelling each other out Ensure the jumper is in the normal off position when testing is finished otherwise low battery and tamper conditions will not be shown Door Window contact 1 Ensure the jumper switch is in the test on position In this position the indicator light will illuminate every time the door contact is operated 2 Fit as described in Mounting me...

Page 13: ... the control unit will activate the alarm immediately irrespective of what armed mode the control unit is in During an alarm the control unit will sound the siren and start to dial the programmed phone numbers If a tamper alarm is activated when the panel is disarmed the system will not dial out Stopping the alarm 1 Key in your PIN code and then press OK The alarm and dialling will stop and the di...

Page 14: ...sure the control unit is in Walk Test mode Low battery display When a detectors batteries are running low it will signal its condition to the control unit when it is activated To be able to clear the display the batteries in the detector will have to be changed Always use alkaline batteries as replacements and ensure the control unit is in Walk Test when taking down detectors After changing batter...

Page 15: ...ult The exit sound can be selected for high or low volume Entry sound Switches on and off the entry countdown beeps 1 Press arrow keys to select the option 2 Press OK to confirm Entry Snd Low is set as factory default The entry sound can be selected for high or low volume Door chime Switches on and off the door chime in the control unit when an entry sensor is activated 1 Press arrow keys to selec...

Page 16: ...mmence an entry countdown upon detection when the system is home armed but cause an instant alarm when fully armed To commence an entry countdown upon detection when the system is fully or home armed These choices are presented during the learning in process and are summarised by the following codes within the control unit B Burglar active when control unit is in armed or home mode O home Omit not...

Page 17: ...nt if the detector has a tamper or low battery condition Multiple door window contact wiring If difficulty is experienced fitting the door window contact because of space etc the PIR sleep feature The PIR has a built in sleep timer to save battery power If there is no movement in front of the PIR for 1 minute the PIR will become ready to signal and movement will now be reported The PIR will sleep ...

Page 18: ...y pressing the Disarm button again for 1 second When arming the system in home mode using the keyfob remote the system will arm and disarm instantly without an exit or entry countdown Keypad remote control accessory Programming 1 Enter the Devices menu and select the Add Device sub menu 2 When prompted by the control unit enter 0000 on the keypad then press TEST The Tx LED will flash showing that ...

Page 19: ... to alarm The smoke detector will produce a warning beep and the LED will flash every 30 seconds if the batteries are near exhaustion The learn test button can be used to test the smoke detector With the control unit in walk test press the learn test button the detector will sound a two tone confirmation and the control unit will confirm Please ensure that you test smoke detectors regularly Remove...

Page 20: ...A having the highest priority If a slot does not have a telephone number stored three dots are displayed indicating the slot is empty In the list only the first 9 digits of the telephone number are displayed Numbers longer than 9 digits are indicated with two dots after the digits displayed Storing telephone numbers 1 In the Tel Numbers menu the cursor will be flashing at location A 2 Press OK 3 E...

Page 21: ...ter saying your address message press OK The display will then allow you to record your specific alarm messages At any time pressing a will abort recording and the message will not be stored The display will return to the menu The maximum length of the address message is 8 seconds When the 8 seconds are over recording will stop automatically and the message recorded will be stored When recording m...

Page 22: ...s 0 on their phone set as the acknowledging signal the control unit will then take the following actions The control unit will go back offline The control unit will continue alarming The control unit will try to dial the next phone number s until two recipients have acknowledged the call Acknowledging with 9 key If the recipient presses 9 on their phone set as the acknowledging signal the followin...

Page 23: ... phone number of the next priority until a total of 2 calls have been acknowledged Terminating with 9 key The two way voice communication will be terminated The control unit will go back offline The alarm will be silenced The control unit will stop dialling The control unit provides the convenience of functioning as a hands free phone You can dial the phone number on the keypad of the control unit...

Page 24: ...re you hang up or the control unit will hang up automatically 30 seconds after except in the situation that the two way communication channel was opened by pressing 1 in this case the control unit will hang up 5 minutes after Hands free call answering If the system is in Disarmed mode or Home mode when the telephone rings you can answer the call without lifting a handset 1 When the telephone rings...

Page 25: ...d the siren tamper must be disabled again by selecting Devices the selecting Program Siren menu and then Siren A T Off Press OK 3 Refit the siren cover 4 Enable the siren tamper by selecting Siren A T On in the Program Siren menu Press OK PIR and door window contact The LED will flash every time the device is activated indicating a low battery and the control unit display will identify the sensor ...

Page 26: ...sticated false alarm filtering that will filter out random fluctuations and responds to genuine movement across field of view it is less sensitive walking directly towards it PIR gives false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR is not mounted above convector heaters or pointing d...

Page 27: ...e receiver with jamming detection Power supply 6V 4 x D alkaline cells 3 years minimum typical service life PIR movement detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AA alkaline cells 3 years minimum typical domestic service life 1 minute sleep timer Movement detection rang...

Page 28: ...r flash they have either been tampered with See trouble shooting page 26 or require a new battery See how to change a battery page 25 www yale co uk E mail info yaleuk com Security Products UK Ltd Wood Street Willenhall West Midlands WV13 1LA Yale is a registered trademark E2 11 03 Downloaded from www ukpanels com ...

Reviews: