23
Factory Settings
*The Master PIN code must be created prior to any other programming of the lock.
**Language retains chosen setting even when lock is reset to factory default.
Hardware Troubleshooting
Cycle lock in both the locked and unlocked positions. If problems are found:
Latchbolt will not deadlock.
a. Either strike is out of alignment or the gap between door and jamb is too great.
Realign strike or shim strike out towards flat area of latchbolt.
Latchbolt does not retract or extend properly.
Latchbolt tail and retractor are not properly positioned:
a. Remove lockset. Look through 2-1/8" hole and verify latchbolt tail is centered
between top and bottom of hole.
b. Remove latchbolt and insert lockset. Look through latchbolt hole and verify retractor
mouth is centered in hole. If not, adjust outside rose plate.
c. If necessary, rebore holes to line up retractor and tail.
Door is binding.
a. Check that door and frame are properly aligned and door is free swinging.
b. Check hinges: They should not be loose or have excessive wear on knuckles.
Settings
Factory Setting
Master PIN Code
Creation
required*
Automatic Relock
3 Seconds
One Touch Locking
Enabled
Privacy Setting
Disabled
Language
English**
Wrong Code Entry Limit
5 Times
Shutdown Time
60 Seconds
Volume Setting
High
All Code Lockout Mode
Disabled
80-9150-0080-010 11-21
Part of ASSA ABLOY