All Code Lockout Mode:
This feature is enabled by the Master PIN code. When enabled, it restricts all user
(except Master) PIN code access. When attempting to enter a code while unit is in Lockout, there will be
an audible lock response. The touchscreen keypad will display a RED locked padlock.
(Main Menu selection #6.)
Automatic Re-lock Time:
After a successful unlock, unit will re-lock automatically after 3 seconds or for a
duration selected in Advanced Lock Settings (Main Menu selection #3 then #1).
Eco Mode:
When enabled, Eco Mode puts unit in low power mode extending life of battery.
Language Setting Mode:
Choose English (1), Spanish (2) or French (3) for lock's voice prompts. (Main
Menu selection #5.)
Low Battery:
When battery power is low, the Low Battery Warning indicator is a flashing red battery icon
on the touchscreen keypad and the Yale logo will flash red on the push button keypad. If battery power is
completely lost, use 9Volt battery override. To use 9V battery override apply 9V battery, in either direction,
to terminals on the keypad for backup power option. Activate the lock and enter your pin code to unlock
door.
Master PIN Code:
The Master PIN code is used for programming and for feature settings.
It must be
created prior to programming the lock.
The Master PIN code will also unlock/lock the lock except when
configured to Accentra system.
Network Module Setting:
With optional Network Module installed, this setting becomes available (Main
Menu selection #7 or #0 with Accentra Module) and allows the lock to connect with a network controller.
One Touch Locking:
When unit is unlocked, activating the lock will lock unit (during Automatic Re-lock
duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is
not
in use
(disabled)
, any
valid PIN code will re-lock the lock. (Main Menu selection #3 then #3.)
Passage PIN Code:
When used to unlock, lock will remain unlocked/open. Lock cannot be locked/secured
until Passage code is entered again.
Privacy Button to Lock Door:
A press of this button will lock the door.
Privacy Mode:
With optional Door Position Switch installed, Privacy Mode enabled thru Menu Mode and
door closed, all keypad functions can be disabled with a press of the Privacy Button. Privacy Mode is
disabled by default. Enable Privacy Mode thru Main Menu selection #3 then #4. With door closed, press
and hold the privacy button until voice prompt indicates Privacy Mode is enabled. Privacy Mode duration
ends when door is opened and voice prompt indicates Privacy Mode is disabled.
Shut Down Time:
Unit will shut down for sixty (60) seconds and not allow operation after wrong code
entry limit (5 attempts) has been met. When unit is in Shut down, the keypad will be flashing.
Tamper Alert:
Audible alarm sounds if attempting to forcibly remove outside lock from door.
User PIN Code:
The User code operates the lock. Maximum number of user codes is 500.
Volume Setting Mode:
The volume setting for PIN code verification is set to
HIGH (1)
by default;
otherwise it can be set to
Low (2)
or
Silent (3)
for quiet areas. (Main Menu selection #4.)
Wrong Code Entry Limit:
After five (5) unsuccessful attempts at entering a valid PIN code, the lock will
not accept a PIN code for the duration of the shut down time. The touchscreen keypad will flash, and a red
padlock symbol will be at the bottom of the keypad. The push button keypad will flash and the Yale icon
will flash blue for the shut down period. The keypad will be available after the shut down time is complete.
Definitions
20
80-9150-0080-010 11-21
Part of ASSA ABLOY