10
VX-8R/E and VX-8DR/E Technical Supplement
Alignment
Wide FM S-Meter Full-Scale Adjustment (S9 LEVEL)
Ì
Connect the test equipment as shown in Figure 2: RX
Alignment Setup.
Ì
Rotate the DIAL knob to select the Alignment Menu
"
S9 LEVEL
" with "
WFM
" icon.
Ì
Set the RF Signal Generator output to 435.100 MHz, at
a level of +20 dBµ, ±20 kHz deviation with a 1 kHz
audio tone.
Ì
Press the [
V/M
] button (the "
" icon will appear on the
display).
Ì
Press the [
F/W
] key two times to store the FM SMeter
Full Scale level.
Ì
Press the [
V/M
] button (the "
" icon will disappear on
the display).
TX Power (HI) Adjustment (HI POWER)
Ì
Connect the test equipment as shown in Figure 1: TX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"
HI POWER
".
Ì
Press the [
V/M
] button (the "
" icon will appear on the
display).
Ì
Press the
PTT
switch to transmit and rotate the DIAL
knob so that the Power Meter reading is 5.0 W (±0.1
W).
Ì
Release the
PTT
switch, and then press the [
V/M
] but-
ton (the "
" icon will disappear on the display).
TX Power (L3) Adjustment (L3 POWER)
Ì
Connect the test equipment as shown in Figure 1: TX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"
L3 POWER
".
Ì
Press the [
V/M
] button (the "
" icon will appear on the
display).
Ì
Press the
PTT
switch to transmit and rotate the DIAL
knob so that the Power Meter setting is 2.5 W (±0.1
W).
Ì
Release the PTT switch, and then press the [
V/M
] but-
ton (the "
" icon will disappear on the display).
TX Power (L2) Adjustment (L2 POWER)
Ì
Connect the test equipment as shown in Figure 1: TX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"
L2 POWER
".
Ì
Press the [
V/M
] button (the "
" icon will appear on the
display).
Ì
Press the
PTT
switch to transmit and rotate the DIAL
knob so that the Power Meter setting is 1.0 W (±0.1
W).
Ì
Release the
PTT
switch, and then press the [
V/M
] but-
ton (the "
" icon will disappear on the display).
TX Power (L1) Adjustment (L1 POWER)
Ì
Connect the test equipment as shown in Figure 1: TX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"
L1 POWER
".
Ì
Press the [
V/M
] button (the "
" icon will appear on the
display).
Ì
Press the
PTT
switch to transmit and rotate the DIAL
knob so that the Power Meter setting is 50 mW (+30
mW/ -20 mW) (VX-8E Type: 0.2W±0.05W).
Ì
Release the
PTT
switch, and then press the [
V/M
] but-
ton (the "
" icon will disappear on the display).
TX Deviation Adjustment (MAX DEV)
Ì
Connect the test equipment as shown in Figure 1: TX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"
MAX DEV
".
Ì
Set the AF Signal Generator output to 50 mVrms with
a 1 kHz audio tone.
Ì
Press the [
V/M
] button (the "
" icon will appear on the
display).
Ì
Press the
PTT
switch to transmit and rotate the DIAL
knob so that the Deviation Meter setting is 4.2 kHz ±
0.2 kHz (USA version) or 4.5 kHz ± 0.2 kHz (EXP/EU
versions).
Ì
Release the
PTT
switch, and then press the [
V/M
] but-
ton (the "
" icon will disappear on the display).
Summary of Contents for VX-8DR/E
Page 5: ...5 VX 8R E and VX 8DR E Technical Supplement Block Diagram ...
Page 6: ...6 VX 8R E and VX 8DR E Technical Supplement Block Diagram Note ...
Page 25: ...25 RF Unit Lot 1 4 VX 8R E Technical Supplement Circuit Diagram ...
Page 27: ...27 RF Unit Lot 5 7 VX 8R E Technical Supplement Circuit Diagram ...
Page 47: ...47 RF 2 Unit Lot 8 15 VX 8R E Technical Supplement Circuit Diagram ...
Page 49: ...49 RF 2 Unit Lot 16 VX 8R E Technical Supplement Circuit Diagram ...
Page 51: ...51 RF 2 Unit Lot 24 VX 8R E and VX 8DR Technical Supplement Circuit Diagram ...
Page 73: ...73 CNTL Unit Lot 1 4 VX 8R E Technical Supplement Circuit Diagram ...
Page 75: ...75 CNTL Unit Lot 5 7 VX 8R E Technical Supplement Circuit Diagram ...
Page 87: ...87 CNTL 2 Unit Lot 8 15 VX 8R E Technical Supplement Circuit Diagram ...
Page 89: ...89 CNTL 2 Unit Lot 16 VX 8R E Technical Supplement Circuit Diagram ...
Page 91: ...91 CNTL 2 Unit Lot 24 VX 8R E and VX 8DR Technical Supplement Circuit Diagram ...
Page 104: ...104 VX 8R E Technical Supplement Note CONNECTOR Unit Lot 1 7 ...
Page 106: ...106 VX 8R E and VX 8DR E Technical Supplement Note CONNECTOR 2 Unit Lot 8 ...
Page 108: ...108 VX 8R E and VX 8DR E Technical Supplement Note MAIN VCO Unit ...
Page 112: ...112 VX 8R E and VX 8DR E Technical Supplement Note MAIN VCO Unit ...
Page 114: ...114 VX 8R E and VX 8DR E Technical Supplement Note SUB VCO Unit ...
Page 117: ...117 VX 8R E and VX 8DR E Technical Supplement ...