background image

FCC ID: K66VX-2500V

 Alignment

Vertex Standard Co., Ltd.

3/6

(Fig 2: J1502 connection for the modulation adjustment)

The transceiver must be programmed for use in the intended system before alignment is
attempted. The RF parameters are loaded from the file during the alignment process.

[Important]
In order to facilitate alignment over the complete switching range of the equipment it is
recommended that the channel data in the transceiver is preset as the chart below. 

        Table.1 RF Ch. List

Frequency(Simplex)

RF Ch. list

Ch. Space

Ver. C

Ch #1

Wide

161.100

MID Frequency(Wide)

 [use in the  SVC47]

Ch #2

Narrow

161.100

MID Frequency(Narrow) [use in the SVC47 ]

Ch #3

Wide

148.100

LOW Frequency  [for PLL VCV  adjustment]

Ch #4

Wide

173.900

HIGH Frequency  [for PLL VCV  adjustment]

The alignment mode is accessed by “Alignment mode” command from the computer whilst
switching on. And it is operated by the alignment tool automatically.

During the alignment mode, normal operation is suspended. Use the alignment tool program
running on PC.

PLL VCV  

 

  

Connect the positive lead of the DC voltmeter to the test point TP1007 (VCV) on the RF-Unit,

as indicated in the figure, and the negative lead to chassis ground.

 

  

Set the transceiver to the high band edge frequency channel, then adjust coil L1017 on the

Unit for 4.25V on the voltmeter.

 

  

Key the transmitter, and adjust coil L1020 on the Unit for 4.25V on the voltmeter. 

Next select to the low edge frequency channel and confirm above 0.80V to 1.50V on the

voltmeter.

 

  

Key the transmitter, and confirm above 1.00V to 1.50V on the voltmeter.

 

PLL Reference Frequency 

 With the wattmeter, dummy load and frequency counter connected to the antenna jack, and
select band center frequency channel, key the transmitter and adjust VR1001 on the RF-Unit, if
necessary, so the counter frequency is within 100 Hz of the channel center frequency for the
transceiver version.

The alignment tool outline

Installation the tool

This alignment tool consists,MS-DOS based, only one execute file " svc47.exe ". You make a

5

4

3

2

1

9

8

7

6

AF Generator

Ground

Summary of Contents for VX-2500V

Page 1: ...lacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Vertex Standard reserves the right to change circuits and alignment procedures in the interest of improved performance without notifying owners Under no circumstances should...

Page 2: ...be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 and 30 C 68 86 F When the transceiver is brought into the shop from hot or cold air it should be allowed time to come to room temperature before alignment Whenever possible alignments should be made with oscillator shields and circuit boards firmly affixed in place Also the test equipmen...

Page 3: ...lignment mode normal operation is suspended Use the alignment tool program running on PC PLL VCV Connect the positive lead of the DC voltmeter to the test point TP1007 VCV on the RF Unit as indicated in the figure and the negative lead to chassis ground Set the transceiver to the high band edge frequency channel then adjust coil L1017 on the Unit for 4 25V on the voltmeter Key the transmitter and ...

Page 4: ...ct the Channel 1 in alignment range Press the Space key on the keyboard to activate the transmitter Press the UP DWN key as need to set the power output to the following specification as indicated on the external wattmeter Tx Power High 25 W 0 5W When the 25Watt level is attained press Enter to lock in the new data 1 Tx Power Low This parameter is used to align TX Low power 5W Press Enter on 1 Tx ...

Page 5: ... on 4 CTCSS Deviation to align CTCSS Deviation Select the Channel 1 in alignment range Press the Space on the keyboard to activate the transmitter and injects a CTCSS test tone Press the UP DWN key as need to set the CTCSS Deviation Wide to the following specification Press Enter to lock in the new data Select the Channel 2 and set the CTCSS Deviation Narrow same as Channel 1 CTCSS Deviation Wide ...

Page 6: ...on will increase around 20 based on the above alignment as follows Actual LTR Deviation Wide 1 00 kHz Actual LTR Deviation Narrow 0 70 kHz 1 Common RX 0 Tight NSQL This parameter is used to align the noise level in squelch Tight It adjusts this alignment RX Tuning after ending Select the MID frequency channel in alignment range Set the SG output level to 2 5dBµV and obey the message 1 Threshold NS...

Reviews: