FCC ID: K66VX-2500V
Alignment
Vertex Standard Co., Ltd.
3/6
(Fig 2: J1502 connection for the modulation adjustment)
The transceiver must be programmed for use in the intended system before alignment is
attempted. The RF parameters are loaded from the file during the alignment process.
[Important]
In order to facilitate alignment over the complete switching range of the equipment it is
recommended that the channel data in the transceiver is preset as the chart below.
Table.1 RF Ch. List
Frequency(Simplex)
RF Ch. list
Ch. Space
Ver. C
Ch #1
Wide
161.100
MID Frequency(Wide)
[use in the SVC47]
Ch #2
Narrow
161.100
MID Frequency(Narrow) [use in the SVC47 ]
Ch #3
Wide
148.100
LOW Frequency [for PLL VCV adjustment]
Ch #4
Wide
173.900
HIGH Frequency [for PLL VCV adjustment]
The alignment mode is accessed by “Alignment mode” command from the computer whilst
switching on. And it is operated by the alignment tool automatically.
During the alignment mode, normal operation is suspended. Use the alignment tool program
running on PC.
・
PLL VCV
□
□
□
Connect the positive lead of the DC voltmeter to the test point TP1007 (VCV) on the RF-Unit,
as indicated in the figure, and the negative lead to chassis ground.
□
□
□
Set the transceiver to the high band edge frequency channel, then adjust coil L1017 on the
Unit for 4.25V on the voltmeter.
□
□
□
Key the transmitter, and adjust coil L1020 on the Unit for 4.25V on the voltmeter.
□
□
□
Next select to the low edge frequency channel and confirm above 0.80V to 1.50V on the
voltmeter.
□
□
□
Key the transmitter, and confirm above 1.00V to 1.50V on the voltmeter.
・
PLL Reference Frequency
With the wattmeter, dummy load and frequency counter connected to the antenna jack, and
select band center frequency channel, key the transmitter and adjust VR1001 on the RF-Unit, if
necessary, so the counter frequency is within 100 Hz of the channel center frequency for the
transceiver version.
The alignment tool outline
Installation the tool
This alignment tool consists,MS-DOS based, only one execute file " svc47.exe ". You make a
5
4
3
2
1
9
8
7
6
AF Generator
Ground