FT
DX
5000 S
ERIES
CAT O
PERATION
R
EFERENCE
CAT
(C
OMPUTER
A
IDED
T
RANSCEIVER
)
O
PERATION
NB
NB
NB
NB
NB
NOISE BLANKER STATUS
Set
1
2
3
4
5
6
7
8
9
10
N
B
P1 P2
;
Read
1
2
3
4
5
6
7
8
9
10
N
B
P1
;
Answer
1
2
3
4
5
6
7
8
9
10
N
B
P1 P2
;
P1 0: Main (VFO-A) Band Receiver
1: Sub (VFO-B) Band Receiver
P2 0: Noise Blanker “OFF”
1: Noise Blanker “ON”
2: Noise Blanker (Wide) “ON”
MW
MW
MW
MW
MW
MEMORY CHANNEL WRITE
Set
1
2
3
4
5
6
7
8
9
10
M
W
P1 P1 P1 P2 P2 P2 P2 P2
11
12
13
14
15
16
17
18
19
20
P2 P2 P2 P3 P3 P3 P3 P3 P4 P5
21
22
23
24
25
26
27
28
29
30
P6 P7 P8 P9 P9 P10
;
Read
1
2
3
4
5
6
7
8
9
10
Answer
1
2
3
4
5
6
7
8
9
10
P1 Memory Channel Number
P2 Memory Channel Frequency (Hz)
P3 Clarifier Dir: Plus Shift, --: Minus Shift
Clarifier Offset: 0000 - 9999 (Hz)
P4 0: RX CLAR “OFF”
1: RX CLAR “ON”
P5 0: TX CLAR “OFF”
1: TX CLAR “ON”
P6 MODE 1: LSB
2: USB
3: CW
4: FM
5: AM
6: FSK (RTTY-LSB)
7: CW-R
8: PKT-L
9: FSK-R (RTTY-USB)
A: PKT-FM
B: FM-N
C: PKT-U
P7 0: (Fixed)
P8 0: CTCSS “OFF”
1: CTCSS ENC/DEC
2: CTCSS ENC
P9: Tone Number (See Page 5: “CTCSS Tone Chart”) 00 ~ 49
P10 0: Simplex
1: Plus Shift
2: Minus Shift
MS
MS
MS
MS
MS
METER SW
Set
1
2
3
4
5
6
7
8
9
10
M
S
P1
;
Read
1
2
3
4
5
6
7
8
9
10
M
S
;
Answer
1
2
3
4
5
6
7
8
9
10
M
S
P1
;
P1 0: COMP
1: ALC
2: PO
3: SWR
4: ID
5: VDD
MX
MX
MX
MX
MX
MOX SET
Set
1
2
3
4
5
6
7
8
9
10
M
X
P1
;
Read
1
2
3
4
5
6
7
8
9
10
N
X
;
Answer
1
2
3
4
5
6
7
8
9
10
N
X
P1
;
P1 0: MOX “OFF”
1: MOX “ON”
N
N
N
N
NA
A
A
A
A
NARROW
Set
1
2
3
4
5
6
7
8
9
10
M
A
P1 P2
;
Read
1
2
3
4
5
6
7
8
9
10
N
A
P1
;
Answer
1
2
3
4
5
6
7
8
9
10
N
A
P1 P2
;
P1 0: Main (VFO-A) Band Receiver
1: Sub (VFO-B) Band Receiver
P2 0: OFF
1: ON
C
ONTROL
C
OMMAND
T
ABLES
OI
OI
OI
OI
OI
OPPOSITE BAND INFORMATION
Set
1
2
3
4
5
6
7
8
9
10
Read
1
2
3
4
5
6
7
8
9
10
O
I
;
Answer
1
2
3
4
5
6
7
8
9
10
O
I
P1 P1 P1 P2 P2 P2 P2 P2
11
12
13
14
15
16
17
18
19
20
P2 P2 P2 P3 P3 P3 P3 P3 P4 P5
21
22
23
24
25
26
27
28
29
30
P6 P7 P8 P9 P9 P10
;
P1 Current Memory Channel
P2 VFO-B Frequency (Hz)
P3 Clarifier Dir: Plus Shift, --: Minus Shift
Crarifier Offset: 0000 - 9999 (Hz)
P4 0: RX CLAR “OFF”
1: RX CLAR “ON”
P5 0: TX CLAR “OFF”
1: TX CLAR “ON”
P6 MODE 1: LSB
2: USB
3: CW
4: FM
5: AM
6: FSK (RTTY-LSB)
7: CW-R
8: PKT-L
9: FSK-R (RTTY-USB)
A: PKT-FM
B: FM-N
C: PKT-U
P7 0: VFO
1: Memory
P8 0: CTCSS “OFF”
1: CTCSS ENC/DEC
2: CTCSS ENC
P9: Tone Number (See Page 5: “CTCSS Tone Chart”) 00 ~ 49
P10 0: Simplex
1: Plus Shift
2: Minus Shift
NL
NL
NL
NL
NL
NOISE BLANKER LEVEL
Set
1
2
3
4
5
6
7
8
9
10
N
L
P1 P2 P2 P2
;
Read
1
2
3
4
5
6
7
8
9
10
N
L
P1
;
Answer
1
2
3
4
5
6
7
8
9
10
N
L
P1 P2 P2 P2
;
P1 0: Main (VFO-A) Band Receiver
1: Sub (VFO-B) Band Receiver
P2 000 - 255
NR
NR
NR
NR
NR
NOISE REDUCTION
Set
1
2
3
4
5
6
7
8
9
10
N
R
P1 P2
;
Read
1
2
3
4
5
6
7
8
9
10
N
R
P1
;
Answer
1
2
3
4
5
6
7
8
9
10
N
R
P1 P2
;
P1 0: Main (VFO-A) Band Receiver
1: Sub (VFO-B) Band Receiver
P2 0: Noise Reduction “OFF”
1: Noise Reduction “ON”
Page 13