Page 128
FT
DX
9000 C
ONTEST
O
PERATION
M
ANUAL
M
ENU
M
ODE
119. SUB FIX 3.5 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 80 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 3500 - 3999 kHz (1 kHz steps)
Default Setting
: 3500 kHz
120. SUB FIX 5.0 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 60 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 5250 - 5499 kHz (1 kHz steps)
Default Setting
: 5250 kHz
121. SUB FIX 7.0 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 40 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 7000 - 7299 kHz (1 kHz steps)
Default Setting
: 7000 kHz
122. SUB FIX 10 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 30 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 10100 - 10149 kHz (1 kHz steps)
Default Setting
: 10100 kHz
123. SUB FIX 14 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 20 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 14000 - 14349 kHz (1 kHz steps)
Default Setting
: 14000 kHz
124. SUB FIX 18 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 17 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 18000 - 18199 kHz (1 kHz steps)
Default Setting
: 18068 kHz
125. SUB FIX 21 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 15 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 21000 - 21449 kHz (1 kHz steps)
Default Setting
: 21000 kHz
126. SUB FIX 24 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 12 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 24800 - 24989 kHz (1 kHz steps)
Default Setting
: 24890 kHz
127. SUB FIX 28 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 10 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 28000 - 29699 kHz (1 kHz steps)
Default Setting
: 28000 kHz
128. SUB FIX 50 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the 6 m
amateur band, when the optional Data Management
Unit (
DMU-9000
) and TFT Display Unit (
TFT-9000
) are
installed.
Available Values
: 50.000 - 53999 kHz (1 kHz steps)
Default Setting
: 50000 kHz
SCOPE G
ROUP
Summary of Contents for FT DX 9000 CONTEST - 2
Page 1: ...FTDX9000 Contest Operation Manual...
Page 2: ......
Page 81: ...Page 79 FT DX 9000 CONTEST OPERATION MANUAL NOTE...
Page 134: ...Page 132 FT DX 9000 CONTEST OPERATION MANUAL NOTE...
Page 157: ...Page 155 FT DX 9000 CONTEST OPERATION MANUAL DUAL RECEIVE UNIT RXU 9000 NOTE...
Page 166: ...Page 164 FT DX 9000 CONTEST OPERATION MANUAL NOTE...