background image

FT-991 CAT Operation Manual

9

CAT

 

(

C

ompuTer

 A

ided

 T

rAnsCeiver

)

 

o

perATion

P1

Function

P2

Digits

125

PRMTRC EQ2 LEVEL

–20 ~ 0 ~ +10 (P2 = –20 ~ –00 or +00 ~ +10)

3

126

PRMTRC EQ2 BWTH

01 ~ 10

2

127

PRMTRC EQ3 FREQ

00 : OFF     01: 1500     02: 1600     03: 1700     04: 1800     05: 1900     06: 2000   ~   18: 3200 Hz

2

128

PRMTRC EQ3 LEVEL

–20 ~ 0 ~ +10 (P2 = –20 ~ –00 or +00 ~ +10)

3

129

PRMTRC EQ3 BWTH

01 ~ 10

2

130

P-PRMTRC EQ1 FREQ

00 : OFF     01: 100     02: 200     03: 300     04: 400     05: 500     06: 600     07: 700 Hz

2

131

P-PRMTRC EQ1 LEVEL

–20 ~ 0 ~ +10 (P2 = –20 ~ –00 or +00 ~ +10)

3

132

P-PRMTRC EQ1 BWTH

01 ~ 10

2

133

P-PRMTRC EQ2 FREQ

00: OFF     01: 700     02: 800     03: 900     04: 1000     05: 1100     06: 1200     07: 1300     08: 1400     09: 1500 Hz

2

134

P-PRMTRC EQ2 LEVEL

–20 ~ 0 ~ +10 (P2 = –20 ~ –00 or +00 ~ +10)

3

135

P-PRMTRC EQ2 BWTH

01 ~ 10

2

136

P-PRMTRC EQ3 FREQ

00 : OFF     01: 1500     02: 1600     03: 1700     04: 1800     05: 1900     06: 2000   ~   18: 3200 Hz

2

137

P-PRMTRC EQ3 LEVEL

–20 ~ 0 ~ +10 (P2 = –20 ~ –00 or +00 ~ +10)

3

138

P-PRMTRC EQ3 BWTH

01 ~ 10

2

139

HF TX MAX POWER

5 ~ 100 (P2 = 005 ~ 100)

3

140

50M TX MAX POWER

5 ~ 100 (P2 = 005 ~ 100)

3

141

144M TX MAX POWER

5 ~ 50 (P2 = 005 ~ 050)

3

142

430M TX MAX POWER

5 ~ 50 (P2 = 005 ~ 050)

3

143

TUNER SELECT

0: OFF     1: INTERNAL     2: EXTERNAL     3: ATAS     4: LAMP

1

144

VOX SELECT

0: MIC     1: DATA

1

145

VOX GAIN

000 ~ 100

3

146

VOX DELAY

30 ~ 3000 msec (P2 = 0030 ~ 3000, 10 msec/step)

4

147

ANTI VOX GAIN

000 ~ 100

3

148

DATA VOX GAIN

000 ~ 100

3

149

DATA VOX DELAY

30 ~ 3000 msec (P2 = 0030 ~ 3000)

4

150

ANTI DVOX GAIN

000 ~ 100

3

151

EMERGENCY FREQ TX

0: DISABLE     1: ENABLE

1

FA

FREQUENCY VFO-A

Set

1

2

3

4

5

6

7

8

9

10

P1  000030000 - 470000000 (Hz)

F

A

P1 P1 P1 P1 P1 P1 P1 P1

11

12

13

14

15

16

17

18

19

20

P1

;

Read

1

2

3

4

5

6

7

8

9

10

F

A

;

Answer

1

2

3

4

5

6

7

8

9

10

F

A

P1 P1 P1 P1 P1 P1 P1 P1

11

12

13

14

15

16

17

18

19

20

P1

;

FB

FREQUENCY VFO-B

Set

1

2

3

4

5

6

7

8

9

10

P1  000030000 - 470000000 (Hz)

F

B

P1 P1 P1 P1 P1 P1 P1 P1

11

12

13

14

15

16

17

18

19

20

P1

;

Read

1

2

3

4

5

6

7

8

9

10

F

B

;

Answer

1

2

3

4

5

6

7

8

9

10

F

B

P1 P1 P1 P1 P1 P1 P1 P1

11

12

13

14

15

16

17

18

19

20

P1

;

FS

FAST STEP

Set

1

2

3

4

5

6

7

8

9

10

P1  0:  VFO-A FAST Key “OFF”

 

1:  VFO-A FAST Key “ON”

F

S

P1

;

Read

1

2

3

4

5

6

7

8

9

10

F

S

;

Answer

1

2

3

4

5

6

7

8

9

10

F

S

P1

;

FT

FUNCTION TX

Set

1

2

3

4

5

6

7

8

9

10

P1  2: VFO-A Band Transmitter: TX

 

3: VFO-B Band Transmitter: TX

P2  0: VFO-A Band Transmitter: TX

 

1: VFO-B Band Transmitter: TX

F

T

P1

;

Read

1

2

3

4

5

6

7

8

9

10

F

T

;

Answer

1

2

3

4

5

6

7

8

9

10

F

T

P2

;

Summary of Contents for FT-991

Page 1: ...FT 991 CAT Operation Reference Book YAESU MUSEN CO LTD...

Page 2: ...lied with your computer for correct data connection Using the USB Cable Refer to figure 2 Note A USB driver is required for remote control from a computer Download the driver from the Yaesu website ht...

Page 3: ...cal characters You may use either lower or upper case characters The commands available for this transceiver are listed in the PC Control Command Tables on the following pages Parameters Parameters ar...

Page 4: ...O O X MA MEMORY CHANNEL TO VFO A O X X X MC MEMORY CHANNEL O O O X MD MODE O O O O MG MIC GAIN O O O O ML MONITOR LEVEL O O O O MR MEMORY READ X O O X MS METER SW O O O O MW MEMORY WRITE O X X X MX MO...

Page 5: ...O INFORMATION Set 1 2 3 4 5 6 7 8 9 10 P1 0 Auto Information OFF 1 Auto Information ON This parameter is set to 0 OFF automatically when the transceiver is turned OFF A I P1 Read 1 2 3 4 5 6 7 8 9 10...

Page 6: ...Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 BY BUSY Set 1 2 3 4 5 6 7 8 9 10 P1 0 RX BUSY OFF 1 RX BUSY ON P2 0 Fixed Read 1 2 3 4 5 6 7 8 9 10 B Y Answer 1 2 3 4 5 6 7 8 9 10 B Y P1 P2 CH C...

Page 7: ...631 002 026 017 115 032 174 047 265 062 365 077 465 092 632 003 031 018 116 033 205 048 266 063 371 078 466 093 654 004 032 019 122 034 212 049 271 064 411 079 503 094 662 005 036 020 125 035 223 050...

Page 8: ...3 011 DVS TX OUT LEVEL 0 100 P2 000 100 3 012 KEYER TYPE 0 OFF 1 BUG 2 ELEKEY A 3 ELEKEY B 4 ELEKEY Y 5 ACS 1 013 KEYER DOT DASH 0 NORNAL 1 REVERSE 1 014 CW WEIGHT 2 5 4 5 P2 25 45 2 015 BEACON INTERV...

Page 9: ...P2 0000 4000 10 kHz step 4 082 RPT SHIFT 144MHz 0 4000 kHz P2 0000 4000 10 kHz step 4 083 RPT SHIFT 430MHz 0 10000 kHz P2 0000 10000 10 kHz step 5 084 ARS 144MHz 0 OFF 1 ON 1 085 ARS 430MHz 0 OFF 1 O...

Page 10: ...ER SELECT 0 OFF 1 INTERNAL 2 EXTERNAL 3 ATAS 4 LAMP 1 144 VOX SELECT 0 MIC 1 DATA 1 145 VOX GAIN 000 100 3 146 VOX DELAY 30 3000 msec P2 0030 3000 10 msec step 4 147 ANTI VOX GAIN 000 100 3 148 DATA V...

Page 11: ...emory 2 Memory Tune 3 Quick Memory Bank QMB 4 QMB MT 5 PMS 6 HOME P8 0 CTCSS OFF 1 CTCSS ENC DEC 2 CTCSS ENC P9 00 Fixed P10 0 Simplex 1 Plus Shift 2 Minus Shift Read 1 2 3 4 5 6 7 8 9 10 I F Answer 1...

Page 12: ...10 L K P1 LM LOAD MESSEGE Set 1 2 3 4 5 6 7 8 9 10 P1 0 DVS P2 0 DVS Recording Stop 1 DVS CH 1 Recording Start Stop 2 DVS CH 2 Recording Start Stop 3 DVS CH 3 Recording Start Stop 4 DVS CH 4 Recording...

Page 13: ...11 12 13 14 15 16 17 18 19 20 P2 P2 P2 P2 P3 P3 P3 P3 P3 P4 21 22 23 24 25 26 27 28 29 30 P5 P6 P7 P8 P9 P9 P10 MS METER SW Set 1 2 3 4 5 6 7 8 9 10 P1 0 COMP 1 ALC 2 PO 3 SWR 4 ID 5 VDD M S P1 Read 1...

Page 14: ...AM 6 RTTY LSB 7 CW R 8 DATA LSB 9 RTTY USB A DATA FM B FM N C DATA USB D AM N E C4FM P7 0 VFO 1 Memory P8 0 CTCSS OFF 1 CTCSS ENC DEC 2 CTCSS ENC P9 00 Fixed P10 0 Simplex 1 Plus Shift 2 Minus Shift...

Page 15: ...1 2 3 4 5 6 7 8 9 10 P R P1 P2 PS POWER SWITCH Set 1 2 3 4 5 6 7 8 9 10 P1 0 POWER OFF 1 POWER ON This command requires dummy data be initially sent Then after one second and be fore two seconds the c...

Page 16: ...X Read 1 2 3 4 5 6 7 8 9 10 R I P1 Answer 1 2 3 4 5 6 7 8 9 10 R I P1 P2 RL NOISE REDUCTION LEVEL Set 1 2 3 4 5 6 7 8 9 10 P1 0 Fixed P2 01 15 R L P1 P2 P2 Read 1 2 3 4 5 6 7 8 9 10 R L P1 Answer 1 2...

Page 17: ...P1 Answer 1 2 3 4 5 6 7 8 9 10 S H P1 P2 P2 Command Bandwidth P2 SSB Narrow SSB Wide CW Narrow CW Wide RTTY PSK Narrow RTTY PSK Wide 00 Default 1500 Hz 2400 Hz 500 Hz 2400 Hz 300 Hz 500 Hz 01 200 Hz...

Page 18: ...P1 0 RADIO TX OFF CAT TX OFF 1 RADIO TX OFF CAT TX ON 2 RADIO TX ON CAT TX OFF Answer T X P1 Read 1 2 3 4 5 6 7 8 9 10 T X Answer 1 2 3 4 5 6 7 8 9 10 T X P1 UL PLL UNLOCK STATUS Set 1 2 3 4 5 6 7 8 9...

Page 19: ...OX STATUS Set 1 2 3 4 5 6 7 8 9 10 P1 0 VOX OFF 1 VOX ON V X P1 Read 1 2 3 4 5 6 7 8 9 10 V X Answer 1 2 3 4 5 6 7 8 9 10 V X P1 XT TX CLAR Set 1 2 3 4 5 6 7 8 9 10 P1 0 TX CLAR OFF 1 TX CLAR ON X T P...

Page 20: ...Copyright 2015 YAESU MUSEN CO LTD All rights reserved No portion of this manual may be reproduced without the permission of YAESU MUSEN CO LTD 1508 C0...