6.
When the program opens, confirm that the file AH031_V0112.SFL is highlighted; if not, click on
it to highlight it.
7.
Click "Configure" if necessary, to change the COM Port.
8.
Click
WRITE.
The onscreen progress bar will indicate programming activity.
9.
When programming has completed, “Confirm” will be displayed.
10.
Disconnect the DC power cable (or turn OFF the power supply for FT-950 and wait a minute,
until the capacitors discharge) and then remove the DB9 serial programming cable.
11.
Thru the access hole on the back of the radio, move the
PGM-SW
to the
LEFT
, (operate
position).
12.
Reconnect the DC power cable (or turn ON the power supply for FT-950).
13.
Press and hold in the [FAST] and [LOCK] keys while turning the radio back on. This resets the
radio and locks in the new software.
14.
Turn the radio off. The main CPU updating process is now complete. Follow the
instructions below to update the EDSP.
EDSP
This procedure is used for uploading new EDSP Software into the FT
-
950 Amateur Transceivers,
from your personal computer, using the RS
-
232C, DB9F to DB9F straight cable.
1.
Turn the FT
-
950 OFF and disconnect the DC power cable (or turn OFF the power supply for FT-
950 and wait a minute, until the capacitors discharge).
2.
Connect a serial RS
-
232C, DB9F to DB9F straight cable to the COM1 connector of your
computer and the 9
-
pin CAT connector on the rear of the transceiver. If you use a USB to serial
adapter, you might need to change the COM Port number.
3.
Reconnect the DC power cable (or turn ON the power supply for FT-950).
4.
While holding the [SHIFT] + [WIDTH] + [CONT] buttons, press the front main power switch to
turn the radio on. You will see [
DSP PRG
]
on the radio display.
NOTE:
I
f you receive a
“communications error”
message on your screen, click
on the
Configure
box and
choose a different COM port
from the drop down menu.
Then click the WRITE button
again.