43
FT-1802M O
PERATING
M
ANUAL
S
CAN
-R
ESUME
O
PTIONS
Three scan-resume modes are available on the
FT-1802M
:
In the “
BUSY
” mode, the scanner will remain halted for as long as there is carrier present
on the channel; after the carrier drops at the end of the other station’s transmission,
scanning will resume.
In the “
HOLD
” mode, the scanner will halt on a signal it encounters. It will not restart
automatically; you must manually re-initiate scanning if you wish to resume.
In the “
3SEC
/
5SEC
/
10SEC
” mode, the scanner will halt for the selected resume time,
after which scanning will resume (whether or not the other station is still transmitting).
The default scan-stop mode is “
BUSY
.” To change the scan-resume mode, use the following
procedure:
1. Press and hold in the [
MHz
(
SET
)] key for one second, then
rotate the
DIAL
knob to select “
41 RESUME
.”
2. Press the [
MHz
(
SET
)] key, then rotate the
DIAL
knob to
select the desired scan-resume mode.
3. Press and hold in the [
MHz
(
SET
)] key for one second to save the new setting and exit to
normal operation.
S