— 7 —
Device parameter
Value
Unit
Operating voltage (from an NMEA 2000 network)
7..16
V
Protection against reverse polarity
Yes
—
Average current consumption
23
mA
Load equivalency number
1
LEN
Operating temperature range (except the sensor)
—40..+80
°С
Weight
62
g
Relative Humidity Measurement
Operating range
0..100
% RH
Measurement resolution
0.04
% RH
Typical accuracy in range 20..80 % RH (1)
± 2
% RH
Accuracy in the rest of range
± 3
% RH
Relative Humidity Measurement
Operating range
—40..+120
°С
Measurement resolution
0.01
°С
Typical accuracy in range 5..60 °C
± 0.3
°С
Accuracy in the rest of range (maximum)
± 1
°С
Note 1:
Normal operating range is 0..80 % RH, beyond this limit the sensor may read a reversible
offset with slow kinetics (+3 % RH after 60 hours at humidity >80 % RH).
Yacht Devices Ltd declares that this product is compliant with the essential requirements
of EMC directive 2004/108/EC.
Dispose of this product in accordance with the WEEE Directive. Do not mix electronic disposal
with domestic or industrial refuse.