8. Mode:
This option allows the Ethernet port to be set to Half Duplex or Full Duplex. Legacy
Ethernet operates in Half Duplex mode which means that devices can either send data or
receive data, but not both at the same time. Full duplex means that devices can send and
receive data at the same time.
2.4.3 Password Setup Page
The password setup page is used to change and enable passwords. A password is required for the setup
pages but is optional for the control page. The password is enabled or disabled for the control page by using
the
Yes
or
No
radio buttons. Enabling the control page password also enables the requirement for a
password when reading/writing XML pages. Enabling the control page password also disables the ability to
communicate with WebRelay-10
TM
using Modbus. Note that when the password is changed, the password
may be displayed in the browser’s history in clear text. It is advisable to clear the browsers history after
setting the password. Passwords may be up to 10 characters.
2.4.4 Control Page Setup Page
This setup page is used to setup parameters that affect the control page as a whole. It is on this page that the
title and main header of the control page is defined, as well as the refresh rate of the control page.