background image

 
 

 

Example for temperature correction: The current set temperature value is 300

℃,

 however, the 

actual temperature is only 290

. So it needs to correct by +10

. Correction method: if the 

current correction value is 00 or -00; then change it to 10. If the current correction value is -20, 
then change it to -10. If the current correction value is 20, then change it to 30. 

 

5.

 

Sleep Mode Set:   

Press “SET” key one time when the LED displays “F-3” and flashes, the unit enters the Sleep 
mode status. At this moment, the LED displays the pre-set value. Press “▲” or “▼” key to 
change the set value. If set value reads “000” that means the unit set in “Sleep” mode releasing 
status. If the display read “100” that means the unit set in “Sleep” mode. Press “SET” key once 
to finish the sleep mode setting, then the unit automatically backup. The user may continue set 
other modes or back from current set mode.   

 

Please note the manufacturer original design will keep in “Free” status without setting 
“Sleep” mode. 

 

6.

 

Wake-up method:   

 

Temperature Down Suspend: If the unit is set at Sleep mode function, after 20min   
idleness, the system will enter the sleep mode automatically, the temperature of soldering will go 
down to 150

  (302

℉) 

/ and the LED displays at “ 150” and flashes

the temperature of 

desoldering will go down to 200

  (392

℉)

 and the LED displays at “ 200” and flashes

Activating the solder wand will disengage the suspend status and the unit will immediately ramp 
up to the preset temperature.   
There are three methods to wake-up the Temperature Down Suspend. 
a

.Ⅰ

  Soldering: Pick up the solder wand 210ESD and shake it gently. 

 

  Desoldering: Pick up the solder wand and press the red suction button on the 
  DIA 100.

 

b. Press any key of the unit.   
c. Turn off the main switch and restart. 

2

  Power off Suspend: If the unit enters the Sleep mode over 40min without wake-up, the unit will 

enter automatically the power off suspend status. It means the heater power will be cut off and 
the LED displays “— — —” and flashes. You can wake it up by pressing “

” key when you 

reuse the iron or turn off the main switch and re-switch on. 

 

7.

 

Fahrenheit and Centigrade (Celsius) temperature selection   

When temperature display window shows "F-4" and blinking, press the "SET" button, at this 
time ,the system enters the degrees Fahrenheit and Centigrade temperature selection function, 
indicating the temperature of the window shows the current status.   Press "▲" or "▼" key to 
change the temperature selection status. It expressed as degrees Celsius temperature value if set 
to “

℃”

; it shows as degrees Fahrenheit temperature if set to 

 

 
WORKING TEMPERATURE 

SOLDERING 
To meet RoHS requirements, the common 60/40 lead solder alloys are not allowed in   

Summary of Contents for LF-853D

Page 1: ...OPERATING MANUAL FOR LF 853D Multi Function SMD Rework System...

Page 2: ...unauthorized alterations 1 Please unscrew the 4 screws under the bottom enclosure when the unit is used at the first time See the procedure on page13 2 Ensure the voltage rating of the unit and your p...

Page 3: ...desoldering tip and the heating element are still remaining hot after being switched off Ensure that you do not touch the tips and the heating elements For your health do not inhale solder fumes You m...

Page 4: ...he power cord must be unplug in before replacing the fuse in AC socket in rear side of the machine Do not unplug the power cord when the power switch is turned off the cooling system will begin to wor...

Page 5: ...ssing keys SET at this time the iron which you set will enter the power off suspend status It means that the heater power is cut off If press then the heater power will be on OPTIONAL SMD TWEEZERS The...

Page 6: ...ep Temperature 150 302 Temperature correction range 99 99 178 178 Default seting 150 302 F 1 000 F 2 00 F 3 000 F 4 Desoldering Power Consumption 170W Temperature range DIA 300 450 572 842 Sleep Tempe...

Page 7: ...8 Temperature decreasing Down 9 Temp Display 10 Heat indicating light 11 SET Function key Desoldering Function Part 12 Temperature increasing UP 13 Temperature decreasing Down 14 Temp Display 15 Heat...

Page 8: ...1 F 2 F 3 F 4 3 Password Setting When the LED displays F 1 and flashes press SET key one time and the unit enters the Password Set status At this moment the LED displays the pre set value Press or ke...

Page 9: ...temperature of desoldering will go down to 200 392 and the LED displays at 200 and flashes Activating the solder wand will disengage the suspend status and the unit will immediately ramp up to the pr...

Page 10: ...60 608 680 Operation for larger joint 370 400 698 752 Too low of a temperature will slow the flow rate of solder and may clog the tip Too a high temperature may burn the P C B Hot air function introdu...

Page 11: ...ss SET key once to finish password setting and the unit will backup mode the user can continue set other modes or back from the setting mode 4 Fahrenheit and Centigrade Celsius temperature selection W...

Page 12: ...in Solder and Desolder wands connect Vacuum tube to VAC Put the hot air gun to the holder 3 Connect AC power cord to mains In Let 4 Turn switch POWER SWITCH to ON position and the switch led will be...

Page 13: ...may clog 3 Add solder to the joint of the component and allow the solder to melt completely for improved desoldering 4 Remove the solder collector and clean it after no more than 200 applications Howe...

Page 14: ...orms it can be removed by careful buffing with 600 800 grit emery cloth isopropyl alcohol or equivalent and then the tinned areas with rosin core solder after the resin core has melted NEW TIPS Applyi...

Page 15: ...process 4 Do not disassemble the pump If the pump or other critical internal components become faulty discontinue its use immediately Please return to your vendor or its authorized repairers for prop...

Page 16: ...ply the proper quantity of solder paste and flux preferably no clean and place install the SMD on the PCB 2 Preheat SMD 3 Soldering Heat the lead frame evenly 4 Washing When soldering is completed was...

Page 17: ...3 Unscrew the barrel nut assembly as in Figures 4 5 FIG 4 FIG 5 4 Remove the tip by using a pliers as in Figures 6 7 FIG 6 FIG 7 5 Insert the stainless tube of the tip back in the barrel to melt the...

Page 18: ...ector as in Figure 11 CAUTION The solder collector is glass and thus retains heat handle with care FIG 11 3 Point the collector down while shaking slightly see Figure 12 and the waste solder will fall...

Page 19: ...10 press turn red knob on the butt of iron 3 Remove solder collector see Figure 11 4 Disassemble the solder collector into 2 pars see Figures 15 16 FIG 15 FIG 16 5 Remove old cotton filter and replace...

Page 20: ...months usage Maintenance for Desoldering Heater and Tip To prevent the desoldering tip being stuck by solder the desoldering tip has to be cleaned by a Probe after every time usage In such ways desol...

Page 21: ...rocedure See Fig 3 SPARE PART Part No 79 460012 Heating element 120Vac 60Hz 600W Part No 79 560012 Heating element 230 240Vac 50Hz 600W INTERCHANGEABLE ACCESSORY 1 INTERCHANGEABLE TIPS Soldering tips...

Page 22: ...21 Desoldering tips for DIA DIA100 2 INTERCHANGEABLE NOZZLES...