PAR Sensor

Some users of the YSI EXO sonde may wish to 
incorporate a photosynthetically active radiation 
(PAR) sensor into their field monitoring equipment.  
This sensor can be added to the YSI EXO2 sonde 
in the form of a special adapter engineered by 
YSI’s Integrated System & Services division. This 
appendix is designed to give potential users of 
this PAR adapter information on how the system is 
configured and the steps necessary to acquire and 
log PAR data with the EXO PAR adapter.

1.2

Overview

Li-Cor PAR sensors are required for the EXO PAR adapter and these sensors can either be supplied to YSI by the 
customer (brass mounting screws provided with the sensor are required for installing on the par system) or can be 
purchased from YSI as part of the complete system. These sensors are then mounted to arms which extend from the 
sonde on either side. Output cables are then attached to the sensors which connect to the EXO PAR adapter, which in 
turn connects to the EXO2 Auxiliary port on the top of the sonde, as show in Figure 1. 

Figure 1 shows the installation of two sensors (one pointing up, the other pointing down), but it is also possible to use a 
single PAR sensor in either an upward or downward looking configuration.

Your EXO PAR system is shipped separate from your EXO2 sonde and can be installed onto the EXO2 sonde following 
these easy steps.

TM

Figure 1

  EXO PAR adapter with Sonde

TM

Summary of Contents for YSI EXO PAR

Page 1: ...USER MANUAL XA00014 EXO PAR PHOTOSYNTHETICALLY ACTIVE RADIATION WITH THE EXO PLATFORM...

Page 2: ...equipment Do not use or install this equipment in any manner other than that specified in this manual The manufacturer is not responsible for any damages due to misapplication or misuse of this produc...

Page 3: ...o certain sections will take you automatically to those locations THIS IS AN INTERACTIVE DOCUMENT TABLE OF CONTENTS 1 Introduction 1 1 PAR Sensor 1 2 Overview 1 3 Components 2 Installation 2 1 Attach...

Page 4: ...er be supplied to YSI by the customer brass mounting screws provided with the sensor are required for installing on the par system or can be purchased from YSI as part of the complete system These sen...

Page 5: ...nsors The EXO PAR system attaches to the EXO2 sonde via an upper and lower clamp system The EXO PAR adapter attaches to the AUX port on the top bulkhead of the EXO2 sonde For shipment and storage the...

Page 6: ...stem Frame Now that your calibration cup extender is installed stand the sonde in an upright position and slide the EXO PAR system frame over the EXO2 sonde The two clamps upper and lower are fastened...

Page 7: ...wer clamp should align with the upper edge of the top chamfer on the clear plastic section covered with the black EXO sonde label Again proper alignment is necessary so the PAR sensor arms are deploye...

Page 8: ...pplied for these cable s connectors plug these connectors when sensors are removed or if only deploying 1 of your 2 PAR sensors When not in use the plugs can be stored in the calibration cup extension...

Page 9: ...quals 2 meters Cable lengths start at 2 meters If the EXO PAR sonde is connecting to a data logger you can use the EXO flying lead cable part number 599008 xx again the xx signifies the cable length f...

Page 10: ...2 Using the Calibration Certificate supplied with your Li Cor PAR sensor you will now enter the multipliers into YSI s Kor software To do so first select Instruments and Sensors and from the list of s...

Page 11: ...ultipliers into YSI s Kor software 3 Now your PAR sensor s are ready to use You can now see PAR data begin to show up in your Kor Dashboard example shown in figure 12 Figure 12 PAR data will begin to...

Page 12: ...Enable sensors 2 Using the Calibration Certificate supplied with your Li Cor PAR sensor you will now enter the multipliers into EXO Handheld Display To do so first select Calibration and from the lis...

Page 13: ...sensors Figure 16 Enter the multipliers exactly as they are on the certificates 3 Now your PAR sensor s are ready to use You can now see PAR data begin to show up in your EXO Handheld Display example...

Page 14: ...ponents 4 2 Ordering Telephone 727 565 2201 USA Monday through Friday 8 00 AM to 5 00 ET Fax 866 778 8431 orders Email YSISystemsOrders Xyleminc com Mail YSI Inc Systems Services Division Attn Order E...

Page 15: ...This page intentionally left blank...

Page 16: ...and re used in the future is central to our work Our products and services move treat analyze monitor and return water to the environment in public utility industrial residential and commercial build...

Reviews: