QUICK START GUIDE
ba75977e04 11/2018
pHotoFlex
®
pH
LED FILTER PHOTOMETER WITH INTEGRATED pH FUNCTION
Page 1: ...QUICK START GUIDE ba75977e04 11 2018 pHotoFlex pH LED FILTER PHOTOMETER WITH INTEGRATED pH FUNCTION...
Page 2: ...ba75977e04 11 2018 pHotoFlex pH Copyright 2018 Xylem Analytics Germany GmbH Printed in Germany...
Page 3: ...data 21 Photometry 23 pH value ORP voltage 24 Part of the process of consequently improving our products is the continuous further development of the range of photometric tests offered and the meter f...
Page 4: ...signal word e g Caution indicates the level of danger CAUTION indicates a possibly dangerous situation that can lead to slight reversible injury if the safety instruction is not followed NOTE indicate...
Page 5: ...pHotoFlex pH Operating modes Measurement The display indicates measurement data in the measured value display Calibration The display indicates a calibration process with calibration information or a...
Page 6: ...ring mode Photometry CAL ZERO In the Photometry measuring mode Select a program for concentration measurement PROG Open menus confirm entries start measurement START ENTER Call up the Configuration me...
Page 7: ...with ESC Menus and dialogs The menus for settings and dialogs in procedures contain further submenus The selection is made with the keys The current selection is highlighted as white text on a black b...
Page 8: ...es Information or operating instructions are indicated by the i symbol They cannot be selected Example Language English Beep Off Illumination On Contrast 48 Temperature unit C Switchoff time 30 min Sy...
Page 9: ...erent language as follows Setting the date and time The date and time are set in the menu Configuration System Continue Date time Operation Inserting a cell To be able to insert cells in the pHotoFlex...
Page 10: ...rt the cell so that it is positioned on the bottom of the cell shaft The cell is ready to be measured 1 Put the fold out cell shaft 2 in an upright position until it locks into place 2 Pull up the hei...
Page 11: ...pH Operation 11 ba75977d04 11 2018 4 Insert the 16 mm cell marking points forward so that it is positioned on the bottom of the cell shaft 5 Close the external light cover 4 The cell is ready to be m...
Page 12: ...sured parameter Concentration is selected 3 Open the Program number display with PROG enter the required program number with the number keys and confirm with START ENTER or from the second concentrati...
Page 13: ...switched on Additionally we recommend to carry out a zero adjustment if the ambient temperature has changed Only perform the zero adjustment against distilled water in an optically perfect cell The ze...
Page 14: ...lue measurement or zero adjustment starts Follow the instructions on the display 1 Connect a suitable pH or ORP electrode to the pHotoFlex pH 2 Press the M key long pressure repeatedly until the pH OR...
Page 15: ...oltage interruption e g empty batteries empty rechargeable battery 1 Submerse the ORP electrode in the sample 2 Press the M key short pressure repeatedly until the measured parameter pH is selected pH...
Page 16: ...ally compatible ones to a collection point set up for recycling purposes Batteries are marked with the crossed out waste container symbol Therefore they may not be disposed with the domestic waste Cle...
Page 17: ...tive gloves etc Cleaning the cells Cells have to be clean dry and free of fingerprints and scratches Therefore clean them regularly Scratches in the glass change the optical characteristics of the cel...
Page 18: ...Charge the rechargeable battery Cause Remedy Software error Operating condition undefined or EMC load unallowed Processor reset Press the START ENTER and PRT key simultaneously Cause Remedy Software e...
Page 19: ...shaft contaminated Clean the cell shaft Dilution set incorrectly Set the dilution Selected program unsuitable Select other program Zero measurement incorrect Perform zero measurement Blank value inco...
Page 20: ...elect buffer solutions suitable for the calibration procedure Buffer solutions too old Use only once Note the shelf life Cause Remedy Cause Remedy pH electrode Junction contaminated Clean junction Mem...
Page 21: ...solutions Measurement procedure not suitable Follow special procedure Cause Remedy Cause Remedy Calibration interval expired Recalibrate the measuring system Dimensions approx 236 x 86 x 117 mm Weight...
Page 22: ...40 V 50 60 Hz 400 mA Output 9 V 1 5 A Connection max overvoltage category II Primary plugs contained in the scope of delivery Euro US UK and Australian Serial interface Connection of the cable AK 540...
Page 23: ...al may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct t...
Page 24: ...2 00 16 00 0 01 U mV 1000 1000 1 T C 5 0 100 0 0 1 T F 23 0 212 0 0 1 Manual temperature input Variable Range Increment Tmanual C 20 100 1 Accuracy 1 digit Variable Accuracy Temperature of the test s...
Page 25: ...pHotoFlex pH ba75977e04 11 2018 25...
Page 26: ...buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications...