in
the dynamic pressure can be computed
Equation 13:4 – Dynamic Pressure using AdvWaterSpeed
𝑃
𝑑
= 0.5 ×
𝑊𝑊𝑑𝑑𝑊𝑊𝑑𝑊𝑊𝑊𝑑𝑊
× (
𝐴𝑑𝑣𝑊𝑊𝑑𝑑𝑊𝑊𝑑𝑑𝑑𝑑
×
𝑊
)
2
Knowing the Dynamic Pressure (Pd) and the Total Pressure (P
0
) – the static pressure
Equation 13:5 – Static Pressure
𝑃
=
𝑃
0
− 𝑃
𝑑
in
the final equation for correcting the
pressure measured by the FlowTracker2 internal pressure sensor is defined in
Equation 13:6 – Corrected Pressure
𝑃
=
𝑃
0
−
0.5 ×
𝑊𝑊𝑑𝑑𝑊𝑊𝑑𝑊𝑊𝑊𝑑𝑊
× (
𝐴𝑑𝑣𝑊𝑊𝑑𝑑𝑊𝑊𝑑𝑑𝑑𝑑
× 2)
2