![Xylem Rule Tournament Series Instruction Manual Download Page 4](http://html1.mh-extra.com/html/xylem/rule-tournament-series/rule-tournament-series_instruction-manual_4774322004.webp)
4
Symptom
Possible Cause
Solution
Reduced flow
Plugged input pump
Clean out thru-hull and strainer.
Close valve and clean debris from around impeller.
Discharge line plugged
with trash
Clean out hose by back-flushing.
Low battery voltage
Check battery condition and charge if necessary.
Kinked discharge hose
If hose is kinked, replace hose.
Wrong polarity
Check to see that brown wire (+) is hooked to positive battery terminal.
Partial airlock
Turn pump off for 15 seconds and then restart.
No water pumped
Wire connections
Make sure no wire connections are corroded through.
Blown fuse
Check fuse to see if it is the correct size. If fuse size is correct and fuse still blows,
check impeller through inlet opening to be sure it is not jammed or stuck with
debris.
Airlock
Backing up your boat may cause air bubbles which will stall the pump. Turn off
pump for 15 seconds to clear air and restart. Make sure pump is below water line
– check to make sure the discharge hose is running continuously upward.
Wire overheated,
melted insulation
Visual check is not enough – a slight pull on each wire will tell if the wires are still
joined. Check to be sure no joints are hanging down into the water.
Combination of jammed
impeller and wrong
size fuse
Be sure impeller is clear of debris and is free to rotate. Reduce fuse to proper
size. Replace damaged wiring.
Trouble-Shooting
XYLEM LIMITED WARRANTY WARRANTS THIS PRODUCT TO BE FREE OF DEFECTS AND WORKMANSHIP FOR A PERIOD OF THREE (3) YEARS. THE WARRANTY IS EXCLUSIVE
AND IN LIEU OF ANY AND ALL OTHER EXPRESS OR IMPLIED WARRANTIES, GUARANTEES, CONDITIONS OR TERMS OF WHATEVER NATURE RELATING TO THE GOODS
PROVIDED HEREUNDER, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE
HEREBY EXPRESSLY DISCLAIMED AND EXCLUDED. EXCEPT AS OTHERWISE PROVIDED BY LAW, BUYER’S EXCLUSIVE REMEDY AND SELLER’S AGGREGATE LIABILITY FOR
BREACH OF ANY OF THE FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT
PAID BY THE BUYER HEREUNDER. IN NO EVENT IS SELLER LIABLE FOR ANY OTHER FORM OF DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CON-
SEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS
OF INCOME, LOSS OF BUSINESS, LOSS OF PRODUCTION, LOSS OF OPPORTUNITY OR LOSS OF REPUTATION. THIS WARRANTY IS ONLY A REPRESENTATION OF THE
COMPLETE LIMITED WARRANTY. FOR A DETAILED EXPLANATION, PLEASE VISIT US AT WWW.XYLEM.COM/RULE, CALL OUR OFFICE NUMBER LISTED, OR WRITE A LETTER
TO YOUR REGIONAL OFFICE.
Congratulations
You’ve just purchased one of the finest quality live/baitwell pumps available in the industry. It was developed after years of experience,
research, and testing by our research staff. Its motor and its shaft seals were specially designed and are manufactured by Xylem Industries to
give years of realiable trouble free performance.
Most early pump failures are due to improper installation and wiring. Please read and follow the instructions carefully and your pump will
provide you with maximum output and the life for which it was designed.
This pump is “Ignition Protected.”
Pump
209FDP
209B
Dual Port
YES 1/2” NPT
NO
Seacock
1”
1”
NOTICE:
All RULE pumps are designed to meet the ABYC standards for the current AIS Decontamination procedure including low pressure water at
120ºF for 130 seconds. Please follow current guidelines for decontamination.