8.5
Maximum number of starts per hour
Power, kW
Starts / h
0.75 - 3
60
4 - 7.5
40
11 - 22
25
30 - 37
16
45 - 75
8
90 - 160
4
200 - 315
3
355 - 500
2
NOTE:
The above table is provided by way of non-exhaustive example. Always refer to the motor
manual.
8.6
Sound pressure
Measured in free field at a distance of one meter from the unit, operating without load.
LpA, dB ± 3
Power, kW
Pump @ min
-1
Pump with standard motor, @ min
-1
2950
1450
950
2950
1450
950
0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15 < 70
< 70
< 70
< 70
< 70
< 70
18.5
< 70
< 70
< 70
70.1
< 70
< 70
22
< 70
< 70
< 70
70.6
< 70
< 70
30
< 70
< 70
< 70
71.8
< 70
< 70
37
70.5
< 70
< 70
73.8
73.4
70.1
45
71.5
70.5
70.0
74.8
71.6
71.2
55
72.4
71.4
70.9
76.9
72.7
71.9
75
73.8
72.9
72.4
78.7
74.1
73.5
90
74.8
73.8
73.3
79.7
74.8
74.2
110
75.7
74.7
74.2
80.0
76.6
75.0
132
76.5
75.6
75.0
80.9
77.2
75.6
160
77.4
76.5
75.9
81.3
77.6
76.6
200
78.5
77.6
77.0
82.3
78.9
78.5
250
79.5
78.6
78.0
82.8
79.7
79.2
315
-
79.7
79.1
-
80.7
-
355
-
80.2
79.7
-
81.1
-
400
-
80.9
80.3
-
-
-
450
-
81.4
80.9
-
-
-
500
-
81.9
81.3
-
-
-