background image

Xylem Inc.

 

8200 N. Austin Avenue 

Morton Grove, Illinois 60053 

Phone: (847) 966-3700 

Fax: (847) 965-8379

www.xyleminc.com/brands/bellgossett

Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. 
© 2012 Xylem Inc.  HS-613B  October 2012  Part No. 514306

Pressure Pilot Test

SEAT AND BALL LEAKAGE
Release the loading force. (Spring tension or air presure).
Open the inlet and outlet valves.

LOOK FOR:

Leakage at the outlet, allow only a 
very small leakage.

INDICATES:

Seat and Ball are worn or held 
open by dirt.

ACTION: Clean parts and retest, replace 

parts if cleaning fails.

STICKING VALVE MOVEMENT
Close the outlet valve and adjust outlet pressure to half of
the inlet. Open and close the outlet valve several times.

LOOK FOR: Outlet pressure on valve closure, 

the pressure should be approxi-
mately the same each time.

INDICATES: Moving parts are sticking.

ACTION: Clean parts and retest, 

replace parts if cleaning fails.

DIAPHRAGM DAMAGE
Close the outlet valve pressurizing the downstream side
of the pilot.

LOOK FOR: Leakage to atmosphere at spring 

button and cover or middle 
diaphragm case vent, allow none.

INDICATES: Broken diaphragms.

ACTION: Replace diaphragms.

IF PILOT PASSES
If the pilot valve passes the above tests it is functional
and the problem is somewhere else, proceed to main
valve.

Pressure Pilot Repair

The instructions describe how to disassemble and rebuild
a pilot. For assembly the steps are reversed. Please note
that if the air test has indicated a specific problem some
of the steps may be skipped. For example, if the test 
indicates a bad diaphragm, there is no need to open the
cover at the other end.
1. Unbolt Lower Cover.

REASSEMBLY TORQUE 175 in-lb.

2. Remove; Screen, Spring Ball Button, Ball and Stem.

Stem should drop out when the valve is inverted.

3. Clean the parts and inspect for wear on seat, ball and

stem. If there is no wear and it appears dirt was the 
problem, assemble and retest the valve.

4. On the Spring Pilot remove the nuts and washers, 

yoke, spring and spring button.

4a. On the air pilots unbolt the large diaphragm case.

Remove the case, diaphragms and button.
REASSEMBLY TORQUE 425 in-lb.

5. Move the pilot valve diaphragm button up and down 

by hand. Movement should be smooth and free.

6. Unbolt the diaphragm cover. Remove it and the 

diaphragm button.
REASSEMBLY TORQUE 175 in-lb.

7. Lift off the diaphragms and inspect for damage.

USE NEW DIAPHRAGMS FOR REASSEMBLY.

8. Lift out the cup and unthread the seat.

ASSEMBLY - THREAD IN UNTIL SEAT BOTTOMS.

9. Clean all gasket and diaphragm sealing surfaces. Use

steel wool or fine (400 grit) paper to clean diaphragm 
seal areas.

10. Clean all parts before reassembly. Polish sliding 

surface with steel wool until movement is free.
REPLACE ALL WORN PARTS.

11. Reassemble the valve. Insert seat gasket and  apply 

non-hardening sealant to seat threads. Start at number 8
above and work backwards.

REASSEMBLY COMPLETED
When the assembly is completed retest with air.

Reviews: