AquaBoost VS duplex
1
2
3
4
5
6
7
8
9
10
RS000012
Typical field piping arrangement for the AquaBoost Variable Speed duplex pumping
package.
1. 1/4 in. tap on the suction manifold for low-suction pressure switch
2. Optional tank
3. Discharge gauge
4. Vibration eliminator
5. Anchor the pipe securely if vibration eliminators are used.
6. If a bypass line is installed, then this valve must be kept closed during normal operation. Do not install a
check valve.
7. Suction gauge, recommended
8. Controller: Aquavar CPC
9. City supply
10.To system
_ _ _ _ Dashed lines indicate field installation.