![Xylem G&L A-C 8300 Series Instruction Manual Download Page 36](http://html1.mh-extra.com/html/xylem/gandl-a-c-8300-series/gandl-a-c-8300-series_instruction-manual_4110812036.webp)
6.8 Dimensions
Cross Section
Figure 19: Cross section
6.9 Reassembly
6.9.1 Assembly of the mechanical seals and bearings without removing the upper half of
the casing
NOTE: All bearings, O-rings, and lip-seals should be replaced with new parts during
assembly. All reusable parts should be cleaned of foreign matter before reassembly.
NOTE: Reassemble the pump by starting on the outboard end (the opposite the
coupling). This end locks the rotating element into position in the casing.
6 Maintenance
34
G&L Pumps Series A-C 8300 Base Mounted Centrifugal Pump INSTRUCTION MANUAL
Summary of Contents for G&L A-C 8300 Series