3.2.3 Application limits
For pump limitations, read the Installation, Operation, and Maintenance manual for the
pump.
The unit must be installed underground, outside of the building.
Data
Description
Media (liquid) temperature
Maximum 40°C (104°F)
pH of the pumped media
5.5–9
Unit depth
Maximum 6 m (20 ft)
Other
For other applications, contact the local sales and
service representative for information.
If installed according to this instruction, then the unit functions in a subsoil water table up to
the ground level.
3.2.4 Dimensions
Drawings
TOP 50
65
80
100 S
150 S
150 L
9050
9065
9080
9100.010
9150.010
9150.020
800
1000
1200
1400
1600
1800
1.5 - 6.0 m
WS007628B
∅ (mm)
Figure 5: Dimensional drawing. Diameter unit: mm. Length unit: m.
3.2.5 Weight
Approximate total weight, excluding the pump:
Table 1: Approximate total weights, excluding the pump
Model
Weight, kg (lb)
2 m
4 m
6 m
Top 50
170 (375)
270 (595)
360 (794)
Top 65
320 (705)
470 (1036)
550 (1212)
Top 80
420 (926)
600 (1323)
820 (1808)
Top 100S
520 (1146)
700 (1543)
910 (2006)
Top 150S
760 (1676)
990 (2183)
1260 (2778)
Top 150L
830 (1830)
1080 (2381)
1360 (2998)
3.2.6 Materials
The unit is made of glass-fiber reinforced polymer, GRP.
3 Product Description
10