WS006952A
5. Remove the impeller:
a) Lock the impeller to prevent rotation.
Use pliers, a screwdriver, or similar.
b) Turn the adjustment screw counterclockwise until the impeller breaks free from
the shaft.
Use a 10 mm hexagon bit adapter (Allen socket) with a 100 mm (4 in.) extension.
WS006953A
c) Pull off the impeller.
Remove the impeller SH
WARNING:
A worn impeller and/or pump housing can have very sharp edges. Wear protective
gloves.