Service item
Action
Insulation
resistance in the
stator
1. Check the insulation between:
• Phase–phase on the stator
• Phase–earth (ground)
The insulation should be > 1 megohm. Use a 1000-VDC megger to test the
insulation.
2. If the resulting value is < 1 megohm, then contact an authorized service shop.
Major overhaul
For a major overhaul, take this action in addition to the tasks listed under Inspection.
Service item
Action
Support and main bearing
Replace the bearings with new bearings.
Mechanical seal
Replace with new seal units.
Change the oil
A paraffin oil with viscosity close to ISO VG32 is recommended. The pump is delivered
from the factory with this type of oil. In applications where poisonous properties are of
less concern, a mineral oil with viscosity up to ISO VG32 can be used.
1
2
WS006203A
1.
Inspection screw
2.
Oil screw
Figure 5: Symbols
Empty the oil
1. Remove the strainer.
See
2. Lay the pump on its side.
Lock the pump with supports to prevent it from rolling over.
3. Remove the oil screw.
There are two oil screws. Either screw can be used for drainage, but it is easier to
drain the oil if both oil screws are removed.
WARNING:
The oil housing may be pressurized. Hold a rag over the oil plug to
prevent oil from spraying out.
4. Turn the pump so that the oil hole faces downwards and let the oil run out.
Maintenance
Flygt 2860.180 Installation, Operation, and Maintenance Manual
25
Summary of Contents for Flygt 2860.180
Page 1: ...Installation Operation and Maintenance Manual Flygt 2860 180...
Page 2: ......
Page 41: ...4x WS001341A Maintenance Flygt 2860 180 Installation Operation and Maintenance Manual 39...