WARNING:
Do not install the starter equipment in an explosive zone unless it is explosion-proof rated.
Three thermal contacts are incorporated in the stator. They are normally closed.
Thermal contacts must never be exposed to voltages higher than 250 V, breaking current
maximum 6 A at a power factor 0.6. It is recommended that the thermal contacts are
connected to 24 V over a separate fuse to protect any other automatic equipment.
Cable charts
Connection locations
WS001021B
L1 L2 L3
T3 T4
T1 T2
15
13
14
4
2
3
1
7
10
5
9
8
6
11
12
17
16
24
22
23
19
20
21
18
1
Starter equipment and main leads (L1, L2, L3)
13
Coil
2
Earth (ground)
14
Transformer
3
Functional ground
15
Capacitor
4
Control leads (T1, T2, T3, T4)
16
Softstarter
5
Phase shifter
17
Level regulator
6
Diode
18
Contactor, start relay or thermal relay
7
Motor cable, minimum 20 m (66 ft.)
19
Thermal detector in stator
8
Screen
20
Thermal detector in main bearing
9
Pump
21
Jumper
10
Crimp connection
22
Terminal board, terminal plate
11
Crimp isolation
23
Leakage sensor
12
Motor protector
24
Stator leads (U1, U2, U5, U6, V1, V2, V5, V6,
W1, W2, W5, W6, Z1, Z5, Z6)
Installation
Flygt 2250 Installation, Operation, and Maintenance Manual
17