Product Description
Products included
Pump model
Approvals
2250.011
Standard
Pump design
The pump is submersible, and driven by an electric motor.
Intended use
The product is intended for moving waste water, sludge, raw and clean water. Always
follow the limits given in
(page 36). If there is a question regarding the
intended use of the equipment, please contact an Xylem representative before
proceeding.
WARNING:
In explosive or flammable environments, only use Ex- or MSHA-approved pumps.
NOTICE:
Do NOT use the pump in highly corrosive liquids.
Particle size
The pump can handle liquid containing particles that correspond to the holes in the
strainer.
Number of holes
Hole dimensions
508
15×45 mm (0.6×1.77 in.)
Pressure class
MT
Medium head
HT
High head
Impeller type
B
Wear resistant
Poly-Life
®
The pump is available with Poly-Life
®
polyurethane wear parts for extra resistance.
Monitoring equipment
The following applies to the monitoring equipment of the pump:
• The stator incorporates thermal contacts connected in series that activate the alarm at
overtemperature.
• The thermal contacts open at 125°C (257°F) and close at 95°C (203°F)