WS001826A
6.4.2 Remove the impeller, alternative 2
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.
Table 4: Applicability
Product code
Pressure class
Open or closed impeller
2190.010
HT
Closed
2201.012
HT
Closed
The illustrations are generic.
1. Remove the strainer.
WS001334B
2. Remove the suction cover.
3. Remove the O-ring.
4. Loosen the impeller:
a) Lock the impeller to prevent rotation.
Use pliers, a screwdriver, or similar.
b) Remove the impeller screw and the washer.
6 Maintenance
Flygt 2190, 2201 Installation, Operation, and Maintenance Manual