background image

www.sensus.com

[email protected]

        

Domo M 

Optical sensor kit with M-Bus output

Description

The Domo M optical sensor is designed for usage with Sensus 

DomoJet and DomoMUK water meters.

 

The device detects the revolutions of the litre pointer. The reading 

is then sent to a standard M-Bus system.

During operation, the module is supplied with power by the M-Bus 

network. A built-in battery provides power supply when the meter 

is temporarily not connected to the M-Bus network.

The sensor is also suitable for usage with the meters of the Modularis 

series. Please check for compatibility with your meter.

Compliance

Maddalena S.p.A. declares that Domo M is compliant with the 
mandatory requirements of the following directives and standards: 
– Directive  2014/30/EU (EMV – Electromagnetic Compatibility)

– Directive  2011/65/EU (RoHS)

The full declaration of EU compliance is available from the follo-
wing website: www.sensus.com

Installation 

(if module is not already mounted on meter)

Connection to the M-Bus network 

The device is deactivated upon delivery. Activation is accomplished 
by connecting the wires to the M-Bus network. After connection, 
allow a few revolutions of the pointer before it starts counting (self-
calibration).

Configuration

The device connected to a standard M-Bus level converter can be 
configured with MiniCom 3 software (www.sensus.com).

Default settings:
•  Baud rate: 2400
•  Primary address: 0
•  Medium: water
•  Initial reading: 0
•  Periodic reading: first day of the month

Cable connections

No polarity

Cable extensions according M-Bus standard

Technical specifications

•  Electronic sensor encapsulated in potting compound
•  Protection rating: IP68
•  Pulse outputs: M-Bus (EN 13757)
•  Pulse factor: 1 pulse = 1 litre (max. 2 pulses/sec.)
•  Alarms: suspected leak, backflow, no consumption
•  Operating temperature: -10 °C ÷ +55 °C
•  Storage temperature: -20 °C ÷ +70 °C
•  Battery service life with M-Bus power supply: up to 12 years
•  Battery service life without M-Bus power supply: 1.5 years
•  Reference standards: EN 61000, EN 14154-3, EN 13757-2 and 3

Installation Manual

Domo M

M-Bus Communication Module 

CABLE 
2 x 0.25 mm

/  L = 1 m

M-BUS

M-BUS

WHITE

BROWN

1

 

Detach the transparent lid 

from the meter; if necessary, 

clean the surface over the 

pointer.

3

Tighten the screw.

4

Apply the tamper-evident 
seal supplied. Check 
correspondence of the RED/ 
BLUE colour of the seal with 
the HOT/ COLD water line 
where the meter is installed.

2

 

Fit the sensor. Press until it is 
even with the cover surface.

MS 1060 INT11 • 10.2021• 0001.6

EN DE FR ES IT

SL SK CZ PL RU UA

Summary of Contents for Domo M M-Bus

Page 1: ...of the pointer before it starts counting self calibration Configuration The device connected to a standard M Bus level converter can be configured with MiniCom 3 software www sensus com Default setti...

Page 2: ...ige Drehbewegungen des Zeigers abwarten bevor die Z hlung Selbstkalibrierung aktiviert wird Programmierung Das an einen Standard M Bus Pegelwandler angeschlossene Ger t kann mit der Software MiniCom 3...

Page 3: ...auto talonnage Programmation L appareil connect une convertisseur standard M Bus peut tre configur avec le logiciel MiniCom 3 www sensus com Param tres par d faut D bit en bauds 2400 Adresse primaire...

Page 4: ...pletar varias revoluciones antes de empezar la contabilizaci n autocalibraci n Configuraci n El dispositivo conectado a un convertidor de nivel M Bus se puede configurar con el software MiniCom 3 www...

Page 5: ...Programmazione Il dispositivo collegato a un convertitore di livello M Bus standard pu essere configurato con il software MiniCom 3 www sensus com Parametri di default Baud rate 2400 Indirizzo primari...

Page 6: ...v omre ju M Bus Po vzpostavitvi povezave pustite da se kazalec pred pri etkom tetja nekajkrat zavrti samodejno umerjanje Konfiguracija Napravo priklju eno na standardni pretvornik M Bus lahko konfigur...

Page 7: ...e nieko ko ot ok ukazovate a ne za ne po ta autokalibr cia Konfigur cia Pr stroj pripojen k tandardn mu prevodn ku logick ch rovn M Bus mo no konfigurova pomocou softv ru Minicom 3 www sensus com Pred...

Page 8: ...pojen umo n te n kolik ot ek ukazatele ne za ne po tat autokalibrace Konfigurace P stroj p ipojen ke standardn mu p evodn ku logick ch rovn M Bus lze konfigurovat pomoc softwaru MiniCom 3 www sensus c...

Page 9: ...y odczeka kilka obrot w wskaz wki zanim rozpocznie ona zliczanie autokalibracja Konfiguracja Urz dzenie pod czone do standardowego konwertera poziomu M Bus mo e zosta skonfigurowane za pomoc oprogram...

Page 10: ...Domo M Sensus DomoJet DomoMUK M Bus M Bus M Bus Modularis Maddalena S p A Domo M 2014 30 EU EMV 2011 65 EU RoHS www sensus com M Bus M Bus M Bus MiniCom 3 www sensus com 2400 0 0 M Bus IP68 M Bus EN...

Page 11: ...Bus DomoM Sensus DomoJet DomoMUK M Bus Bus M Bus Modularis Maddalena S p A Domo M 2014 30 EU EMV 2011 65 EU RoHS www sensus com M Bus M Bus M Bus MiniCom 3 www sensus com 2400 0 0 M Bus IP68 M Bus EN...