6.5.2 Fill with oil
The pump is delivered with a tasteless, odorless, medical white oil of paraffin type that fulfills
FDA 172.878.
Examples of suitable oil types are the following:
• Statoil MedicWay 32
™
• BP Enerpar M 004
™
• Shell Ondina 927
™
• Shell Ondina X430
™
1. Thread the hose of the hand-pump through both of the holes into the seal chamber.
WS003632A
2. Pump oil into the seal chamber until it overflows through the opposite hole.
Table 19: Approximate oil quantities
Pump
Quantity, L (qt)
7030
2.4 (2.5)
7035
3.6 (3.8)
7040
3.8 (4.0)
3. Replace the O-rings with new ones.
4. Remount the oil plugs and tighten.
Tightening torque: 44 Nm (33 ft-lb)
5. Remount the outer screws for the oil plug.
Tightening torque: 76 Nm (57 ft-lb)
6.6 Pumps with MAS 801: Replace the PEM
1. Remove the entrance cover and cable leads.
2. To remove the terminal block and rail, follow this procedure:
a) Disconnect the remaining leads from the terminal block.
6 Maintenance
66
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual