Screened cables
WS008809A
Screened SUBCAB - ground
Functional ground
Cable without sep. ground conductor
Ground conductor is stranded ground cores
T1/T2 & T3/T4 (if applicable)
Twisted together
WH
shrink hose
GN/YE
shrink hose
L1
L2
L3
T1 T2
T3 T4
Bare wire
Figure 33: Cable without separate ground conductor. Ground conductor is stranded ground cores.
MiniCAS II
24 V AC/DC
R
CC
P
C
L2
L1
10
2
6
7 +
T1
T15
T2
FLS10
5 -
11
1
12 VDC
9
8
10S
4
3
WS002623C
C Pump contactor
CC Control circuit
L1 Caution light (leakage)
L2 Caution light (stator over-
temperature)
P Pump main supply
R Reset switch
4.8 Check the impeller rotation
CAUTION: Crush Hazard
The starting jerk can be powerful. Make sure nobody is close to the unit when it is started.
If the propeller rotates in the wrong direction, then the pump lifts up and rotates, which can
damage the cables.
1. Start the motor.
2. Stop the motor after a few seconds.
3. Check the propeller rotation.
The correct direction of propeller rotation is clockwise when you look at the pump from
above.