10
Terminal base Connection, Data Line, and Signal Line Regulation
1. Power Input Terminal
DC 12V Input and power consumption of 2.5A.
AC 24V Input and power consumption of 2.2A.
Video Output Terminal
Video Signal Output: CVBS 1.0 Vp-p 75 Ohms BNC.
2. Alarm Input/ Output Terminal
Each Speed Dome camera is equipped with 6 external alarm inputs and 2 sets of alarm outputs
(1 set NO and 1 set NC). Alarm Input voltage: 5.6V max and Alarm Output Specification: 0.35A
120V AC/ 0.5A 24V AC.
3. Communication Control Input/ Output Terminal
RS-485 Input Terminal has two terminal points (D+, D-), using the twisted pair wire to connect
onto the next Speed Dome Camera.
10pin Green Terminal Block
SENSOR/RELAY
PIN No. Definition
1 GND
2 Sensor
1
3 Sensor
2
4 Sensor
3
5 Sensor
4
6 Sensor
5
7 Sensor
6
8 NO
9 COM
10 NC
4
pin Green Terminal Block
RS
485
C
ONNE
C
TOR
PIN No. Definition
1 D-
2 D-
3 D+
4 D+
2
pin Green Terminal
P
o
w
er
-I
np
ut
PIN No. Definition
1
AC24V
2 GND
2
pin Green Terminal
P
o
w
er
-I
np
ut
PIN No. Definition
1 DC12V
2 GND
Summary of Contents for XSD35ZDN