XVision XSD35ZDN User Manual Download Page 1

Model:

XSD35ZDN

Colour 550 TVL 560x Zoom

Speed Dome Camera

CCTV

Model:

XSD35ZDN

Colour 550 TVL 560x Zoom 
Speed Dome Camera

Before you begin

Please unpack the box carefully and identify that all the parts are present.

Do not cut the cables, this will void the warranty.

Make sure you use only the recommended power supply. Damage caused to the unit by 

incorrect voltage or wiring is not covered by the warranty.

USER MANUAL

Summary of Contents for XSD35ZDN

Page 1: ...d Dome Camera Before you begin Please unpack the box carefully and identify that all the parts are present Do not cut the cables this will void the warranty Make sure you use only the recommended power supply Damage caused to the unit by incorrect voltage or wiring is not covered by the warranty USER MANUAL ...

Page 2: ...g Options 11 8 System Installation 12 9 Operation 13 10 MENU Operational Description 16 11 Quick Reference Table 18 12 Quick Reference Table 19 13 Troubleshooting 20 14 Specifications 21 The author assumes no responsibility for any errors or omissions that may appear in this document nor does the author make a commitment to update the information herein 2 ...

Page 3: ...ppropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product Do not install the product in an environment where the humidity is high Unless the product is waterproof or w...

Page 4: ...tion key indicates the order sequence Example 2 8 ENTER meaning press the function key 2 8 and then ENTER 3 Indicate messages from the device and is shown on the control keyboard LCD display 4 n indicates the ID number of the nth device ID numbers ranges from 001 127 2 Symbol Description 4 DEVICE 001 _ ...

Page 5: ...l Pan Speed up to 300 Sec and Tilt Speed up to 200 Sec l Horizontal Rotation of 180 l Built in 6 Alarm Inputs and one Relay Output l Two types of Alarm out signal are provided NO and NC l Remote Control via RS 485 l Connects up to 127 Speed Dome Cameras l Supports PELCO Protocol D and P Protocol l PC control software is applicable l AC24V or DC12V Power Input l Built in heater device and fan to ma...

Page 6: ...6 DC12V TYPE 1 DC Adaptor x1 2 Power Line x1 3 Power Connector x1 4 Speed Dome x1 5 Speed Dome Cover x1 4 Contents ...

Page 7: ...acket Corner Mount Bracket 2 Machine Housing 3 Transparent Cover 4 ID Number Protocol Baud Rate Setting 5 Alarm Input or Output Video Output Power Input Terminal 5 Component and Structure Description 7 Wall Mount Ceiling Mount Corner Mount ...

Page 8: ...ber Setting Connection of up to 127 Speed Dome Cameras each camera has its own ID Number Setting 000 then the image display will show DEVICE N A Does not affect setup DIP Switch setting shown below 6 Camera Setting ...

Page 9: ...PS BOLD Default Settings SW2 Protocol Settings SW2 Baud Rate Settings Settings Switch Number 5 6 7 8 Off Off Off Off On Off Off Off Off On Off Off On On Off Off Protocol NATIVE PELCO Reserved Reserved Speed Dome automatically detects the type of PELCO Protocol No switch settings are required to set D and P Protocols BOLD Default Settings ...

Page 10: ...put voltage 5 6V max and Alarm Output Specification 0 35A 120V AC 0 5A 24V AC 3 Communication Control Input Output Terminal RS 485 Input Terminal has two terminal points D D using the twisted pair wire to connect onto the next Speed Dome Camera 10pin Green Terminal Block SENSOR RELAY PIN No Definition 1 GND 2 Sensor 1 3 Sensor 2 4 Sensor 3 5 Sensor 4 6 Sensor 5 7 Sensor 6 8 NO 9 COM 10 NC 4pin Gre...

Page 11: ...11 Outdoor Installation Structure Diagram Wall Corner and Ceiling Mount 7 Camera Mounting Options Wall Mount Corner Mount Ceiling Mount ...

Page 12: ...2 on the green controller terminal connector then connect the wire from D on Speed Dome to connection A2 on the same terminal connector You have now completed the RS485 telemetry connection Connecting to a monitor Simply connect a phono lead not supplied to the camera s video lead using a BNC to Phono adaptor and connect the phono jack on other end into VIDEO IN on your monitor Powering the Speed ...

Page 13: ...l will appear on the LCD display CAMERA OPERATION and ZOOM CONTROL The Keyboard Controller enables simple control of the Pan Tilt and Zoom functions on the Speed Dome camera see diagram to right Panning Camera Move the joystick in the direction required i e move to the right to pan right Tilting Camera Move the joystick either up or down to tilt Zooming Camera Zoom in by rotating the joystick to t...

Page 14: ... 2 4 again to setup more preset points CALL PRESET POINT Press CALL button enter the assigned preset number and press ENTER the LCD will display and the speed dome camera will move to that specified preset point Example 1st preset point 1 ENTER 28th preset point 2 8 ENTER CHANGE PRESET POINT To change the preset point please follow the setup guide in the PRESET POINT SETUP SAVE TO PRESET XXX GO PR...

Page 15: ...you do not wish to set all 32 preset points set _ _ _ as the last preset point Example If you wish to set only 4 preset points you must set the 5th preset point to _ _ _ The system will auto pan as follow 1 2 3 4 1 2 3 4 AUTO SCAN Activate Auto Scan Under control mode assume device 1 when the LCD displays Press CALL enter 9 9 ENTER key the speed dome camera will slowly precede 360 auto scan Deacti...

Page 16: ...T D N MODE AE D N MODE CDS CDS LEVEL D N MODE DAY D N MODE NIGHT FILTER DLY 0 255 1 15 SEC DAY NIGHT display is applicable only to cameras withDAY NIGHTfunction Only when EXPOSURE MODE AUTO can D N MODE AEbeeffective FILTER DLY is applicable only to AE and CDS mode BACKLIGHT BACKLIGHT BLC Level ON OFF 0 80 CAMERA SET UP WBC MODE WBC MODE Auto WBC MODE Hue MWB Data WBC MODE Indoor WBC MODE Outdoor ...

Page 17: ...nt Serial Number DWELL TIME sec 001 128 Alarm retention period retention meaning forever halt HOME SET UP HOME FUNCTION ON OFF Homing Function PRESET POSITION 1 32 35 82 Select Homing Point RETURN TIME min 001 030 Homing Time start counting from the instant when the device stopped moving AUTOPAN SETUP AUTOPAN GROUP 001 004 AUTOPAN 005 006 as simple manner it does not need setup AUTOPAN INDEX 001 0...

Page 18: ... Z Control Zoom Wide Push the Joystick Counterclockwise Select device No Key CAM Manual Operation Focus Far FOCUS FAR Manual Operation focus Near FOCUS NEAR Iris Control to Bright IRIS OPEN Iris Control to Dark IRIS CLOSE Preset Point Setup Enter Preset No 1 32 35 82 Press Key SET PRESET Call Preset Point Enter Preset No 1 32 35 82 Press Key GO PRESET Start Preset Mode Enter 99 Press Key GO PRESET...

Page 19: ... Exit Main Menu MENU Functions Method of Operation Cursor Up Push the Joystick Forward FOCUS NEAR Cursor Down Push the Joystick Backward FOCUS FAR Menu Enter IRIS OPEN Menu Exit IRIS CLOSE Decrease Push the Joystick to the Left Increase Push the Joystick to the Right 12 Quick ReferenceTable KEYBOARD MENU SETUP MENU SETUP MODE ...

Page 20: ...ectrical plug has been disconnected or switched off 3 Unable to control the Speed Dome Camera l Check whether the ID position is correct l Check whether the communication control output or input terminal RS 485 In Out JACK of the Speed Dome Camera and the control wire are properly connected l Check whether the communication control terminal RS 485 JACK and control wire is properly connected l Plea...

Page 21: ...Angle 0 to 90 Precision Degree Horizontal Vertical 0 25 Preset Points 80 1 32 35 82 Preset Points Group setup 6 Groups ID position setup 1 127 Camera Sensor Type 1 4 CCD Image Sensor Scanning System 2 1 Interlace Total Pixels 795 H X 596 V 410k PAL Effective Pixels 752 H X 582 V 440k PAL Horizontal Resolution 550 TVL B W 600 TVL Colour 500 TVL Minimum Illumination 0 01 Lux S N Ratio More than 48dB...

Page 22: ...tch ON 15 C 4 C OFF 25 C 3 C Controller Interface RS 485 Alarm Input 6 Alarm Inputs Alarm Output 1 Set NC Normal close 1 Set NO Normal open 0 35A 120V AC 0 5A 24V DC Alarm Output Mode Lock onto the last Alarm Input Environment Operating Temperature 10 C to 50 C Relative Humidity 0 to 90 Mechanism Type Wall Mount Ceiling Mount Height 280mm 315mm Diameter Ø220mm Ø220mm Weight Standard 3 4Kg 3 2Kg 22...

Page 23: ...23 ...

Page 24: ... for any Xvision product please contact your local distributor LIMITED WARRANTY This product is supplied with a 1 Year warranty The Warranty excludes products that have been misused including accidental damage and damage caused by normal wear and tear In the unlikely event that you encounter a problem with this product it should be returned to the place of purchase ...

Reviews: