XtremeAIR SP05-I36 Installation Manual & User Manual Download Page 8

P a g e  

8 | 10

 

 

11. SPECIFICATION 

 

 

Body Design 

Non-Magnetic 1.0 mm Stainless Steel, Satin Finish 

 

Power Rating 

120V/60Hz (USA & Canada standard) 

General Input Power 

158W (150W + 4x2W) 

Motor Input Power 

150 W each 

Ampere 

1.3 A 

Levels Of Speed Control 

4 Levels 

Maximum  Airflow 

900CFM 

Noise Level 

Approximately 1.5 – 6.0 sones or 33 – 54 dB 

Number Of Motors 

Single Motor 

Motor Type 

Single Chamber Ultra Quiet 

Fan Type 

Squirrel Cage blower 

Filtration Type 

Heavy Duty Stainless Steel Baffle Filter 

Illumination 

4 LED lights, 2W Maximum/each 

Venting Size 

Top 6 inches Round 

Interference Protection 

Radio Frequency Interference Protected 

Note 

Specification subject to change without notice. 

12. TROUBLESHOOTING 

 

1.

 

If the range hood or lights does not operate after installation: 

 

Check if the range hood has been plugged in.  Make sure that all power has been turned back ON. Check if the fuse is not blown and all electrical wiring is 
properly connected. 

 

Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs. See 

replacing the light bulbs 

on Page 13. 

2.

 

The range hood vibrates when the blower is on: 

 

The range hood might not have been secured properly on to the ceiling or wall. 

 

Check if the motor is secured in place.    If not, then tighten the motor in place. Check if the blower wheel is damaged. 

3.

 

The bower or fan seems weak: 

 

Check that the duct sized used is at least 6”.  Range hood WILL NOT function efficiently with insufficient duct size & loosely secured.

 

Check if duct is clogged or if damper unit (half-circular flapper) is not installed correctly or opening properly. A tight mesh on a side wall cap unit might 

also cause restriction to the air flow.

4.

 

The lights work but the blower is not spinning at all, is stuck or is rattling. 

 

The blower might be 

jammed or scraping the bottom due to shipping damage. Please contact us immediately.

 

The motor is defective, possibly seized - change the motor.

5.

 

The hood is not venting out properly

:

 

 

 

Make sure the distance between the stove top and the bottom of the hood is within 26” and 30” in distance. 

Due to different ceiling 

height configurations, recommended height may not be applicable.

 

Reduce the number of elbows and length of ductwork. Check if all joints are properly connected, sealed, and taped.

 

Make sure the power is on high speed for heavy cooking.

6.

 

The hood is noisier than normal 

 

The duct is not secure and causes vibration.

 

The smaller duct size than required is being used.

7.

 

Control panel is not active 

 

Check to make sure the auto function is not on.

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SP05-I36

Page 1: ...P a g e 1 10 INSTALLATION GUIDE USER S MANUAL IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY ISLAND MOUNT RANGE HOOD Model SP05 I 36 42 PX05 I 36 42...

Page 2: ...the range hood WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact...

Page 3: ...ically through the roof with a minimum of a 6 or larger vent work ALWAYS when possible reduce the number or transitions and turns If a long duct run is required increase duct size from 6 to 7 or 8 If...

Page 4: ...WER SLOT CHIMNEY L H C LOWER HOOK CHIMNEY MANUAL BOOK DIMENSION TABLE D1 D2 D3 D4 D5 D6 D7 D9 10 5 inch 3 8 inch 12 5 8 inch 23 0 inch 19 0 inch 23 6 inch 35 4 41 3 inch 8 25 inch Ceiling mount bracke...

Page 5: ...3 on each side STEP 1 MARKING CEILING BRACKET A Put a thick protective covering over counter top cook top or Range to protect from damage or debris B Find and mark the center point directly above you...

Page 6: ...SHUT OFF this range hood will be shut off for every approx 2 hour You can re start operation as usual after it was shut off 2 30 HOUR REMINDER after 30 hours of use the timer 8 will be flashing To cl...

Page 7: ...CLEAR CLEANING REMINDER When blower motor starts to rotate cumulative running time will be shown in Power On Elapsed Digital Timer 8 This timer icon flashes when 30 hours is up and reminds user to cle...

Page 8: ...properly on to the ceiling or wall Check if the motor is secured in place If not then tighten the motor in place Check if the blower wheel is damaged 3 The bower or fan seems weak Check that the duct...

Page 9: ...oth Do not use corrosive or abrasive detergent e g Comet Power Scrub EZ Off oven cleaner or steel wool scoring pads which will scratch and damage the stainless steel surface For heavier soil use liqui...

Page 10: ...uthorized service facility Therepaired unit will be returned at The Company s expense For specific instructions on how to obtain warranty service for your product contact XtremeAir USA by emailing sup...

Reviews: