background image

 

www.XtremeAirUsa.com

                                                                    PAGE 

6

 

 

STEP #6: INSTALLING OIL TUNNEL & BAFFLE FILTERS 

 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
IMPORTANT:    BEFORE YOU BEGIN 

 

1.  This unit is equipped with TOUCH SENSITIVE CONTROLS so please DO NOT PRESS.    A light touch and hold on the required button for a matter of a (1) one 

second is all that is needed. 

2.  TOUCH THE ENTIRE BUTTON.    See the following illustration: 

 

 
 
 
 
 
 

 

 

 
 

 
 
 
 
 
 
 
 

 

Importance Notice: 

1.  2 ½ HOUR AUTOMATIC SHUT OFF: this range hood will be shut off for every approx. 2 ½ hour.    You can re-start 

operation as usual after it was shut off. 

2.  30 HOUR REMINDER:    after 30 hours of use, the timer (8) will be flashing. To clear it, please refer to “G-To Clear 

Cleaning Reminder” on page 7. 

 
TYPE 2:  TOUCH BUTTON   

1.

 

(1) To power ON/OFF, and to activate power-off delay timer.   

2.

 

(2) To decrease blower (motor) speed, decrease timer value, and enter timer mode.   

3.

 

(7) To increase blower (motor) speed, increase timer value, and cumulative timer reset.   

4.

 

(3) Blower (motor) is running light indicator. 

5.

 

(4) Shows current blower (motor) speed (1-4).   

6.

 

(5) Lights up when lights turned on.     

7.

 

(6) To turns ON/OFF lights.   

8.

 

(8) Indicates the accumulated time the system is running.   

9.

 

(9) Indicates the length of time left for delay off function.   

10.

 

(10) Lights up when auto-shutdown delay timer function is on.     

VS. 

For best results, Start the range hood 
before cooking and allow it to operate 
several minutes after the cooking is 
completed to clear all smoke and odors 
from the kitchen.

   

 

Entire button covered and lightly touched. 

 

CORRECT 

Button is NOT completely covered

 

INCORRECT 

10. RANGE HOOD OPERATION 

 

 

2. Lift the lower angle of the baffle 

filter up above horizontal level.   

3. Slide (backward) forward into slot. 

To  remove  the  baffle,  please 
reverse the process.

 

 

 

1.  Angle (higher point) baffle filter 

toward front of hood (oil tunnel 
side).

 

 

OIL TUNNEL:

 Drop oil tunnel into 

the inside hood body slot.

 

 

 

Summary of Contents for PRO-X PX05-I36

Page 1: ...www XtremeAirUsa com PAGE 1 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY INSTALLATION GUIDE USER S MANUAL ISLAND MOUNT RANGE HOOD Model Pro X Series PX01 I30 I36 I42 ...

Page 2: ...allation in this manual is intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professionals and in accordance with all applicable codes and standards including fire related construction When cutting or drilling into the wall or ceiling do not damage electrical wiring and other utiliti...

Page 3: ...pe all joints with aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If the roof or wall cap has a damper you may opt out from usage of your range hood supplied damper for some models only For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommen...

Page 4: ... MUST BE MOUNTED TO A WEIGHT BEARING CEILING SUPPORT SYSTEM OR FRAMEWORK BEING USED IS STABLE AND SECURE ON THE CEILING ABLE TO SUPPORT AT LEAST TWICE THE WEIGHT OF THE HOOD DIMENSION TABLE 7 PARTS SUPPLIED 8 GENERAL INSTALALTION DIAGRAM D8 Total bracket length See formula below D8 CEILING HEIGHT FROM FLOOR D11 D10 D9 D10 Clearance from bottom of hood to cook top 26 to 30 as your designed D11 Cook...

Page 5: ...crew driver to slightly tight all 4 bolts D Have a third person raise up the island range hood into its position Hood should be directly under the support brackets E Attach the hood to the support brackets at all 4 corners with bolts F Connect the ductwork to the range hood Use aluminum tape to secure the pipe joint area G Connect power plug Slide upper slot chimney USC into place connecting the 6...

Page 6: ...de 3 7 To increase blower motor speed increase timer value and cumulative timer reset 4 3 Blower motor is running light indicator 5 4 Shows current blower motor speed 1 4 6 5 Lights up when lights turned on 7 6 To turns ON OFF lights 8 8 Indicates the accumulated time the system is running 9 9 Indicates the length of time left for delay off function 10 10 Lights up when auto shutdown delay timer f...

Page 7: ...l Timer 8 This timer icon flashes when 30 hours is up and reminds user to clean the baffle filters After cleaning the filters and when the motor is not in use touch and hold Increase Value button 7 over 3 seconds to reset the timer Please note that turning off the system will not reset the Power On Elapsed Digital Timer 8 Body Design Non Magnetic 1 0 mm Stainless Steel Satin Finish Power Rating 12...

Page 8: ...rts to clean without proper instructions Disassembly is recommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal operation clean range hood and all baffle spacer filter grease tunnel oil container regularly Regular car...

Page 9: ...www XtremeAirUsa com PAGE 9 15 LIMITED WARRANTY ...