background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
     
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
WARNING

 

-

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE   

                        THE FOLLOWING: 

 

ƒ

Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer 

 

PRODUCT: 

Do not remove permanently affixed labels, warnings, or plates from the product.    This may void the warranty. 

Do not try to alter the hood 
 

INSTALLATION

:

 

The installation in this manual is intended for qualified installers, service technicians or persons with similar 

qualified background.    Installation and electrical wiring must be done by qualified professionals and in accordance with all 
applicable codes and standards, including fire-rated construction.  When cutting or drilling into wall or ceiling; do not 
damage electrical wiring and other utilities.  Due to the size and weight of this range hood, two people installation is 
recommended.  Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any 
parts for installing, cleaning or servicing. 
 

VENTTING: 

For kitchen range or cook top ventilating use only.    DO NOT use to exhaust hazardous or explosive materials 

and vapors.  Ducted fans MUST always be vented to the outdoors.  DO NOT vent exhaust into spaces between walls, 
crawl spaces, ceiling, attics or garages.  Use only metal ductwork.  Old duct work should be cleaned or replaced if 
necessary to avoid the possibility of a grease fire.    Check all joints on duct work to insure proper connection and all joints 
should be properly taped. 

 
ELECTRICAL: 

All electrical wiring must be properly installed, insulated and grounded.  Before servicing or cleaning unit, 

turn power OFF and un-plugged   

 
OPERATION: 

Use high settings on cooking range only when necessary.  Keep all fan, baffle, spaces, filter, grease 

tunnel, oil container and grease-laden surfaces clean.  Grease should not be allowed to accumulate on fan, baffle, 
spaces, filter, grease tunnel, and oil container.    Never allow the filters to become blocked or clogged. Do not allow foreign 
objects, such as cigarettes or napkins, to be sucked into the hood. 

 
WARNING: 

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 

 Never leave surface units unattended at high settings.    Boilovers cause smoking and greasy spillovers   

    that may ignite.    Heat oils slowly on low or medium settings. 

       

 Always turn hood ON when cooking at high heat or when greasy food. 

       

 Clean ventilating fans frequently.    Grease should not be allowed to accumulate on fan or filter. 

       

 Use proper pan size. Always use cookware appropriate for the size of the surface element.

 

 
WARNING: 

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE,   

            OBSERVE THE FOLLOWING: 
       

 

SMOTHER FLAMES

 with a close fitting lid, cookie sheet, or metal tray, then turn off the burner. Be careful   

            to prevent burns. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 
       

 NEVER PICK UP A FLAMING PAN - you may be burned. 

       

 DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 

       

 Use an extinguisher ONLY if: 

            – You know you have a class ABC extinguisher, and you already know how to operate it. 
            – The fire is small and contained in the area where it started. 
      – The fire department is being called. 
            – You can fight the fire with your back to an exit. 

 

 

IMPORTANT SAFETY INSTRUCTIONS-continue

                                                 

www.XtremeAirUsa.com

                                                                    PAGE 

3

 

Summary of Contents for PRO-X PX01-I36

Page 1: ...IDE USER S MANUAL PRO X SERIES Island Mount Range Hood PX01 I36 PX01 I42 PX04 I36 PX04 I42 PX05 I36 PX05 I42 Model IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY www XtremeAirUsa com PAGE 1 ...

Page 2: ...ot following instructions for installation contained in the following text DANGER To avoid the possibility of explosion or fire do not store or use combustible flammable or explosive vapors and liquids such as gasoline inside or in the vicinity of this or any other appliance Keep items that could explode such as aerosol cans away from cook top burners ovens and range hoods Do not store flammable o...

Page 3: ...alled insulated and grounded Before servicing or cleaning unit turn power OFF and un plugged OPERATION Use high settings on cooking range only when necessary Keep all fan baffle spaces filter grease tunnel oil container and grease laden surfaces clean Grease should not be allowed to accumulate on fan baffle spaces filter grease tunnel and oil container Never allow the filters to become blocked or ...

Page 4: ...l cap has a damper do not use damper supplied for some models only with the range hood For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 6 or bigger vent work ALWAYS when possible reduce the number or transitions and turns If long duct run is...

Page 5: ...nformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances TOOL YOU WILL NEED Maker or pencil Stud finder Measuring tape Powered screwdriver or drill Flat Phillips screwdrivers Level Drill with 1 1 4 7 9 mm drill bits Jigsaw or keyhole saw Cabinet Jack optional PA...

Page 6: ... the ceiling bracket onto the ceiling 5 Trace a circle where the ducting will go 6 Mark the 4 corners where you will screw Important Due to the weight and size of this unit ceiling bracket must be mounted to a weight bearing ceiling support system or framework being used is stable and secure on the ceiling able to support at least twice the weight of the hood 1 Place chimney bracket against ceilin...

Page 7: ...ote first make sure your ductwork is pulled down about 6 inch longer than the chimney 1 Slide inner and outer chimney sleeve over support brackets covering the ceiling bracket 2 Screw inner chimney into place at the top of ceiling bracket 3 Lift the outer chimney all the way up to ceiling USE screw driver to hold it from falling down Note To avoid scratching the chimney extend the inner upper chim...

Page 8: ...kets 2 connect power plug and connect the ductwork to the range hood HINT Due to the heavy weight of this range hood use vertical jack to lift and hold the hood in place is highly recommend it 3 Screw hood to the support brackets on all 4 corners as show 5A A DROP OIL TUNNEL INTO THE INSIDE HOOD BODY SLOT REFER TO LEFT FIGURE B INSTALL BAFFLE FILTERS refer to Figure on the left for the following t...

Page 9: ... the kitchen Button functions 1 To power ON OFF the range hood and to activate power off delay timer 2 To decrease blower motor speed decrease timer value and enter timer mode 7 To increase blower motor speed increase timer value and cumulative timer reset 3 Lights up when blower motor is running 4 Shows current blower motor speed 1 4 5 Lights up when lights turned on 6 To turns ON OFF lights 8 In...

Page 10: ...shut down E To clear cleaning reminder When blower motor starts to rotate cumulative running time will be shown in Power On Elapsed Digital Timer This timer icon flashes when 30 hours is up and reminds user to clean the baffle filters After cleaning the filters and when the motor is not in use touch and hold Increase Value button over 3 seconds to reset the timer Please note that turning off the s...

Page 11: ...ecured properly on to the ceiling Check if the motor is secured in place If not then tighten the motor in place Check if the blower wheel is a damaged Check that the duct sized used is at least 6 Range hood WILL NOT function efficiently with insufficient duct size loosely secured Check if duct is clogged or if damper unit half circular flapper is not installed correctly or opening properly A tight...

Page 12: ... scratch and damage the stainless steel surface For heavier soil use liquid degrease such as Formula 409 or Fantastic brand cleaner If hood looks splotchy stainless steel hood use a stainless steel cleaner to clean the surface of the hood Avoid getting cleaning solution onto or into the control panel Follow directions of the stainless steel cleaner CAUTION Do not leave on too long as this may caus...