Xtreme XPD0815SL User & Installation Manual Download Page 4

Xtreme Power Conversion Corporation

XPDU’s User’s Manual

Page 4

Uninterruptible Power Supply

Specifications

MODEL NUMBER Input Power Connection

Outlets

Voltage

Circuit 

Breaker

Dimensions (W

 

x

 

D

 

x

 

H)

Weight

Switched PDU
XPD0815SL

Detachable 10 ft, 5–15P

(8) 5–15/20R

120V

15A

17 x 3.75 x 1.7 in (1U) 4.4 lbs

SPD-0215

IEC C14 inlet

(2) 5–15R

120V

N/A

5.4 x 6.0 x 2.5 in

2.0 lbs

Transformer PDU
XPD-IT60A

3 ft, L6–30P

(12) 5–15/20R

208V input

30A

19.0 x 18.0 x 3.5 in 

(2U)

137 lbs

208V to 208/104V, 

208V to 240/120, 

240V to 240/120V output

XPD-AT15A

Detachable 3 ft, IEC C14

(8) 5–15R front + (8) 

5–15R rear

208V input

15A

19.0 x 10.5 x 3.5 in 

(2U)

19.7 lbs

120V output

Basic PDU - 15A & 20A models
XPD815HV

12 ft, 5–15P

(8) 5–15R

120V

15A

17 x 3.75 x 1.7 in (1U) 2.6 lbs

XPD1415HV

12 ft, 5–15P

(14) 5–15R

120V

15A

17 x 3.75 x 1.7 in (1U) 3.5 lbs

XPD1420HV

12 ft, 5–20P + L5–20P

(14) 5–20R

120V

20A

17 x 3.75 x 1.7 in (1U) 4.8 lbs

XPDU-IEC

IEC C20 inlet

(2) IEC C19 + (10) IEC 

C13

230V

15/20A 17 x 3.75 x 1.7 in (1U) 4.4 lbs

Basic PDU - 30A & 50A models
XPD24C13V

6 ft, L6–30P

(24) C13

208V

30A

66.0 x 1.8 x 1.8 in 12.0 lbs

XPD31

6 ft, L6–30P

(2) L6–30R + (2) L6–20R 

+ (4) 6–15/20R

240V

30A

19.0 x 4.7 x 3.5 in (2U) 9.0 lbs

XPD32

6 ft, L6–30P

(2) L6–30R + (4) L6–20R

240V

30A

19.0 x 2.4 x 3.5 in (2U) 7.5 lbs

XPD33

6 ft, L6–30P

(4) IEC C19 + (8) IEC C14

240V

30A

19.0 x 2.4 x 3.5 in (2U) 6.0 lbs

XPD34

6 ft, L14–30P

(2) L6–30R + (4) L6–20R 

+ (12) 5–20R

240/120V

30A

19.0 x 4.7 x 3.5 in (2U) 9.5 lbs

XPD35

Pigtail

(2) L6–30R + (4) L6–20R

240V

50A

19.0 x 2.4 x 3.5 in (2U) 7.0 lbs

XPD36

Pigtail

(4) IEC C19 + (8) IEC C14

240V

50A

19.0 x 2.4 x 3.5 in (2U) 6.8 lbs

XPD37

Pigtail

(2) L6–30R + (4) L6–20R 

+ (12) 5–20R

240/120V

50A

19.0 x 4.7 x 3.5 in (2U) 10.0 lbs

Value PDU

XPS1215HVP

6 ft, 5–15P

(12) 5–15R

120V

15A

17 x 1.5 x 1.7 in (1U) 1.4 lbs

1. Model XPDS1015HV and XPS1020HV and XPS1215HVL also provides surge protection for connected equip

-

ment. The Surge Energy is 2,000 Joule.

2. Model XPD1415HVA and XPD1420HVA and XPD2420VA60 has Amp meter & alarm : 

The total electrical current used by XPD1415HV will be displayed on the digital meter in amperes. The audible 

alarm will sound when the load exceeds 80% of the rated load. In the event of an audible alarm, verify that the 

combined load does not exceed the rated load.  

Summary of Contents for XPD0815SL

Page 1: ...XPDU 15A 20A Models User Installation Manual www xpcc com 2022 Xtreme Power Conversion Corporation All rights reserved Rev 4 4 22 ...

Page 2: ... Manual Page 2 Uninterruptible Power Supply Table of Contents Important Safety Instructions 3 Specifications 4 Environmental 5 Receiving Inspection 5 Installation 5 Connecting 6 Caution 6 Obtaining Service 7 Xtreme Power Conversion Limited Warranty 8 ...

Page 3: ...security and IT applications To reduce the risk of fire connect only to a branch circuit with over current protection in accordance with the National Electric Code ANSI NFPA 70 3KVA To reduce the risk of electrical shock with the installation of this PDU equipment and the connected equip ment the user must ensure that the combined sum of the AC leakage current does not exceed 3 5mA Rack Mount Inst...

Page 4: ...A models XPD24C13V 6 ft L6 30P 24 C13 208V 30A 66 0 x 1 8 x 1 8 in 12 0 lbs XPD31 6 ft L6 30P 2 L6 30R 2 L6 20R 4 6 15 20R 240V 30A 19 0 x 4 7 x 3 5 in 2U 9 0 lbs XPD32 6 ft L6 30P 2 L6 30R 4 L6 20R 240V 30A 19 0 x 2 4 x 3 5 in 2U 7 5 lbs XPD33 6 ft L6 30P 4 IEC C19 8 IEC C14 240V 30A 19 0 x 2 4 x 3 5 in 2U 6 0 lbs XPD34 6 ft L14 30P 2 L6 30R 4 L6 20R 12 5 20R 240 120V 30A 19 0 x 4 7 x 3 5 in 2U 9...

Page 5: ...esigned to minimize any shipping damage In the unlikely case that the XPD needs to be returned to XPD please use the original packing material Since XPD is not responsible for shipping damage incurred when the system is returned the original packing material is inexpensive insurance PLEASE SAVE THE PACKING MATERIALS Standard Package includes a PDU b Standard 19 rack mounting hardware if applicable...

Page 6: ...nect the AC Input power cord into a three pole three wire easily accessible dedicated recommended grounded receptacle or one that does not share a circuit with a heavy electrical load only Caution 1 Do not install this device if there is not at least 10 meters 30 feet or more of wire between the electrical out let and the electrical service panel 2 This device features an internal protection that ...

Page 7: ... ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask th...

Page 8: ...than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifi cations or c the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions Any t...

Reviews: