OPERATION
16
Step 7.
Place the CFT cell into the piping and screw
the unions back onto the ends of the new cell. Tighten
the thread. The cell can be positioned either way. In
fact, we suggest to reverse the cell every time you
clean it to extend the life of the cell.
Step 8.
Plug the power cord into the lower corner of
the controller.
Step 9.
Restart the pool pump and salt chlorine generator. The controller should light up and
the pool pump should operate.
Step 10.
Any air in the duct should be drained from
the open safety valve. When the water begins to
squirt from the safety valve, close the valve.
Step 11.
After a couple of minutes, the controller
display will show a salt value of between 2700 and
3400 and the “Power” and “Generating” LEDs should
be light on.
Summary of Contents for 90151
Page 18: ...PARTS LIST 17 ...