XtraVac CM640 Chamber Machine Operation and Parts Manual
XtraVac Packaging Machines
419 E. 11th Ave. North Kansas City, MO 64116 USA
CM640 Chamber Machine
+1 (800) 728-2999 [email protected]
11
3.1 Memory set display (A): display the current memory set (e.g. ”3” means the 3
rd
set)
3.2 Vacuum time display (B): display the current setting of vacuum time (unit: 1/s)
3.3 Nitrogen filling time display (C): display the current setting of nitrogen filling time
(Unit: 1/s)
3.4 Sealing time display (D): display the current setting of sealing time (unit: 0.1/s)
3.5 Cooling time display (E): display the current setting of cooling time (unit: 0.1/s)
3.6 Memory release key (F): press key for modifying memory function
3.7 Memory input key (G): press key for locking memory function
3.8 Reserved key (H): key reserved for further use.
3.9 E-stop key (I): make timing function stop, and release the upper lid.
3.10 Time increase key (J): press key for time adding
3.11 Time decrease key (K): press key for time reducing
3.12 Sequence of trial run:
3.12.1 Connect the power.
3.12.2 Connect the pneumatic source by quick connector.
3.12.3 If the running condition sounds smoothly, it’s clockwise rotating. If the machine
doesn’t work, please turn off the machine immediately. Then, change the power
wires.
※
Attention: remember to ground the machine.
3.12.4 Packaging test:
(A) Test the sealing temperature and adjust the sealing time in accordance with Chapter 3
page 10(D).
(B) Test the vacuum degree and adjust the vacuum time in accordance with Chapter 3 page
10(B).
3.12.5 If everything is OK, operate the machine according to the instructions in Chapter 4 for
normal production.
Summary of Contents for CM640